- 34 -
CC
Pull out the relay connection of flame rod
connectors and then display
maintenance information [0y].
M
Does the [0y]
indicate [01] ~ [07]
(remaining flame)?
NO
YES
Clean or replace Main Burner
and Flame Rod Electrode.
Replace Burner Control Assy.
J. Error Code [65] (Malfunction of Water Volume Control Motor) is displayed.
Turn the power off and then, turn it on.
NO
NO
YES
YES
Is the
voltage to the
Motor OK?
*1
Replace Burner Control Assy.
Is the
voltage to the
Motor OK?
(When Motor
operates)
*2
Replace Burner Control Assy.
Replace Water Control Assy.
B
T
L
*1 Measure the voltage of connector .
Between Red and Black wires: 8 ~ 16 VDC
B
*2 Measure the voltage of connector .
Between White and Black wires: 8 ~ 16 VDC
Содержание PH-28CDVSN
Страница 16: ...Operational Flow Chart Maintenance Information 16...
Страница 18: ...18...
Страница 19: ...MAINTENANCE INFORMATION SHOWN IN LED DISPLAY OF REMOTE CONTROL ABOVE 19...
Страница 44: ...44...
Страница 53: ...Schematic Disassembly PH 28RIFS 53...
Страница 54: ...Schematic Disassembly PH 28ROF 54...
Страница 55: ...Schematic Disassembly PH 28RIFS PH 28ROF 734 55...
Страница 58: ...Schematic Disassembly PH 28CIFS 58...
Страница 59: ...Schematic Disassembly PH 28COF 59...
Страница 60: ...Schematic Disassembly PH 28CIFS PH 28COF 734 60...
Страница 63: ...Schematic Disassembly PH 28RDVS 63...
Страница 64: ...Schematic Disassembly PH 28CDVS 64...
Страница 65: ...Schematic Disassembly PH 28RDVS PH 28CDVS 65...