GRAND AUDITION MK2 CASCADING
Up to three Grand Audition MK2s can be cascaded and cabled/wired together or controlled with WLAN
from a computer or tablet. To do this, use an Ethernet switch or a WLAN router with at least three LAN ports
(see WLAN router example below). The IP addresses must be set for each device separately one after the
other in the browser-based Grand Audition app under DEVICES before the first joint setup; set a sepa-
rate IP address for each device in the defined address space (e.g., master unit: 192.168.2.99, slave unit 1:
192.168.2.98, slave unit 2: 192.162.2.97) and then confirmed by clicking
Change & Restart
.
Now connect each of the WLAN router’s LAN ports to the Grand Audition MK2’s Ethernet interfaces
with Ethernet cables (min. CAT5e) and switch on the devices. Enter the IP address 192.169.2.99 into your
browser’s address line, press ENTER (
) to confirm, and log in (LOGIN). The Grand Audition MK2 with this IP
address is now automatically the master unit. Click the
DEVICES
tab. Under
FIRST SLAVE IP ADDRESS
in
Linked
Grand Auditions
, enter the IP address of the first slave unit (e.g., 192.168.2.98). Then enter the IP address of
the second slave unit (e.g., 192.168.2.97) under
SECOND SLAVE IP ADDRESS
. The devices will be immediately
recognized and the virtual controls under
CHANNELS
and
VOLUMES
expanded accordingly.
Now connect the master unit’s LINK OUTPUT L + R with slave unit 1’s LINE INPUT L + R and slave unit 1’s LINK
OUTPUT L + R with the LINE INPUT L + R for slave unit 2 using balanced XLR cables.
IP Address 192.168.2.99
IP Address 192.168.2.99
Master
IP Address 192.168.2.99
Slave 1
IP Address 192.168.2.98
Slave 2
IP Address 192.168.2.97