PALM

®

 MicroBeam User Manual - 0202 Z

The PALM

®

 MicroBeam - Survey

PALM

®

 CapMover

5.7 PALM

®

 CapMover

The motorized PALM

®

 CapMover was developed 

for fast positioning with highest precision and 

quick exchange of the cap for sample collection.
The LPC (LaserPressureCatapulting

pat.

) collection 

device can be mounted to the PALM

®

 CapMover. 

This way, the cap is positioned and moved via joy-

stick to check for the catapulted specimen.

Figure 10 

CapMover/Manipulator

5.7.1

Control Apparatus

At the front of the control apparatus there are two 
buttons, a joystick and an LED.
The LED essentially indicates the operational 
readiness.  In the event of an error or a circuit 

overload, this LED will extinguish. In this case, dis-
connect the apparatus from the power supply and 
ascertain the cause of the error. You should not 

switch on the control apparatus until after having 
done this.

Figure 11 

Control Apparatus

Brief extinguishing of the LED also indicates a 
change of speed, as well as the saving of a new 
reference position.
The joystick serves to move the CapMover arm - 

and consequently the cap - in two dimensions.  
The buttons have the following functions:

Left button

If the button is pressed briefly, the CapMover arm 
moves to the reference position that is currently 
saved. By pressing the button a second time the 

arm moves back to the last position it was moved 
to. 
If the arm has been moved from the reference 

position with the joystick, then this position is 
accepted as the last targeted position.
If the button is pressed for a while, then the cur-
rent position is saved as the new reference posi-

tion. The LED will extinguish briefly as a 
confirmation signal.

Right button

If the button is pressed briefly, this will switch 
between the 'fast' and 'slow' speed ranges. The 

LED will extinguish as a confirmation signal with 
each change of the speed range. 
The faster speed range is suitable for examination 

at a low optical magnification factor, whilst the 
slower speed range is useful in the case of high 
magnification.
Prolonged pressing of the button will cause the 

arm to move outside of the objective area - for 
example in order to take up a new cap. 
Speed change, joystick and the functions of the 

left button are deactivated in this position. 
Renewed activation of the right button will cause 
the arm to be retrieved and the cap to be moved 

to the saved reference position.

5.8 Mechanical Manipulator

Instead of the PALM

®

 camper the mechanical 

manipulator can be used for cap movement via 
hand-driven knobs.
With the mechanical manipulator you can clamp a 
take-up instrument (e. g. a capillary or a metal rod 

to hold conventional injection cannulae or the LPC-
instrument) and move it in the x, y or z-direction.
For more details see the manipulator manual.

  1 cap
  2 cap mover
  3 lever for cup height adjustment

1

2

3

Содержание MicroBeam

Страница 1: ...PALM MicroBeam User Manual PALM MicroBeam User Manual 0202 Z ...

Страница 2: ...o responsibility for any errors that may appear Printed June 2002 Second Edition The following technologies have been patented by P A L M Microlaser Technologies Laser catapult technology Laser Pressure Catapulting LPCpat Patents US 5 998 129 EP 879408 B1 and others Three dimensional laser beam positioning system Patents US 5 689 109 EP 679325 B1 and others Additional patents pending P A L M Micro...

Страница 3: ...ing Risks Infectious Material 9 4 7 4 Remaining Risks EMV 10 4 7 5 Remaining Risks Fire Extinction 10 4 8 How to Ensure a Safe and Ecological Disposal 10 5 The PALM MicroBeam Survey 11 5 1 PALM ControlUnit 12 5 2 Laser Interface 12 5 3 Laser 13 5 4 Microscope Adapter 13 5 5 Microscope Zeiss Axiovert 200 14 5 5 1 Fluorescence attachment 15 5 6 PALM RoboStage 15 5 7 PALM CapMover 16 5 7 1 Control Ap...

Страница 4: ...1 Simultaneous Fluorescence Observation 22 8 Trouble Shooting List 23 8 1 Laser is not cutting 23 8 2 No video image 24 8 3 Shift between drawing and cutting 24 9 Maintenance of the PALM MicroBeam 25 9 1 Laser 25 9 2 Microscope 25 9 2 1 Cleaning of the Optical Parts 25 9 2 2 Cleaning When Actually Dirty 25 10 Technical Data 26 10 1 Electricity 26 10 2 Nitrogen Laser 26 ...

Страница 5: ...nly partly observed The warranty extinguishes in case the customer opens the laser housing or uses the device for other than the specified purposes If used parts are replaced by similar parts which are however not identical to those recommended by the manufacturer in this manual P A L M Microlaser Technologies AG is only liable if the product supplied has already been faulty before the parts were ...

Страница 6: ...tem should be installed in a room which is adequately large about 6 square meters and well aired There should be a free space available about 90cm above the table and all shelves wall cup boards etc should be removed Figure 1 Dimensions Nature of the floor vibration free if not spe cial working table recommended and even Load carrying capacity for steel or granite table 400 kg Minimum space needed...

Страница 7: ...croBeam is a laser device of Class 1 M with no special safety requirements if operated according to the instructions given in this user man ual Built in is a Laser of class 3B It bears a potential risk A direct or reflected beam must not strike the unprotected eye do not look directly into the beam In service case the device has to be operated by the service staff or an authorized representative o...

Страница 8: ...ing safety markings and the type plate exist and are legible Replace miss ing or illegible safety markings or type plate Figure 2 Safety Markings and Type Plate Caution The safety markings on the device must always be clearly visible and legible and must strictly be observed P A L M MicrolaserTechnologies Class M1 Identification label ...

Страница 9: ... 26 4 7 Pay Attention to Remaining Risks and Preventive Measures 4 7 1 Remaining Risks and Protective Measures Laser Remaining risks The laser works with invisible light When the casing is open the laser pertains to the laser protection class 3B The high power radiation leads to dimmed sight of the eye The casing must always kept closed and locked and may only be opened by the ser vice staff of P ...

Страница 10: ...adiation in the same room where the PALM MicroBeam is placed 4 7 5 Remaining Risks Fire Extinction To extinguish fire use sand carbon dioxide or fire extinguishing powder Never ever use water because of the electric dangers 4 8 How to Ensure a Safe and Ecological Disposal Dispose the following materials in an environmen tally friendly way Microscope lamps with incorporated bulb or individual mercu...

Страница 11: ... the following chapters Figure 3 Survey of the PALM Micro Beam P A L M MicrolaserTechnologies P A L M MicrolaserTechnologies 1 2 3 4 5 6 7 8 12 10 11 13 14 15 16 9 1 microscope 2 CCD video camera 3 lmicroscope stage 4 CapMover option 5 filter wheel option 6 fluorescence illumination option 7 laser interface and laser 8 control unit 9 monitor 10 power supply fluo illum 11 control unit filter wheel ...

Страница 12: ... the optical focus of the microscope at the object plane and to adjust the laser energy Figure 5 Laser Interface This is a prerequisite for precise laser micromanip ulations with highest precision Furthermore the laser position stays stable which allows to routinely work with the system without time consuming search for the laser beam focus LED color green yellow red indication status ready busy e...

Страница 13: ...aser to the microscope The laser beam is guided into the microscope and deflected into the objective Figure 6 Microscope adapter The especially designed beam splitter see Figure 7 Pos 2 allows to connect the fluorescence illu mination lamp and the filter wheel to the system and simultaneously use fluorescence illumination with laser application Notice The correct laser focus setting is done by the...

Страница 14: ...he microscope The filter revolver has to be in the position in which the beam splitter reflects the laserbeam This position is labeled with Laser In case of installed fluorescence attachment option it is possible to use also the installed beam splitters of the fluorescence filtersets only in case of original used P A L M beam splitters The two diaphragms in the epifluorescence channel must be open...

Страница 15: ... integrated to speed up routine work In PALM RoboStage there is a holding frame into which the specimen slides and or Petri dishes can be clamped Both transversal sides of the object slide are held by a snap on clip One longitudinal side of the slide entirely rests on the holding frame This reduces the risk that extremely thin slides will bend by the adhesion force of the immersion oil 1 1 filter ...

Страница 16: ...e arm moves back to the last position it was moved to If the arm has been moved from the reference position with the joystick then this position is accepted as the last targeted position If the button is pressed for a while then the cur rent position is saved as the new reference posi tion The LED will extinguish briefly as a confirmation signal Right button If the button is pressed briefly this w...

Страница 17: ... image handling software for easy image selection and editing as well as archiving With the integrated network card you have the possibility to connect your computer with your local network If you want to connect it please contact your local area network administra tor Notice Depending of the Camera Adapter the com puter monitor only shows a section of the area visible in the ocular Caution The ca...

Страница 18: ...lter block or slider in front of the objective is switched into the correct position called laser FL on adjustment failed that the FL shutter in the microscope is open FL appears in the display adjustment aid is in left position Notice If the red system LED of the control unit doesn t turn off automatically please witch off the PALM ControlUnit and after 10 seconds switch it on again Should the LE...

Страница 19: ...ase see figure 14a The smallest avail able cutting size can only be achieved within the center of the laser focus using as little energy as possible The catapulting is effected by a laser beam wid ened to the appropriate diameter with its focus placed underneath the specimen to be catapulted please see figure 14b The laser beam is guided through the epifluo rescene channel of the microscope and is...

Страница 20: ...tion the laser focus position has to be changed independent from the microscope focus The Laser Focus Correction is done motorized A high precision DC stepping motor moves the cor responding lens Focus setting is conveniently con trolled and regulated on the monitor screen by means of the of the PALM RoboSoftware The dis play allows relocating selected laser focus settings Laser energy and focus i...

Страница 21: ...ic tool spanning at least the monitor screen start automatic cutting with the Cut function reduce the laser energy with the Page down key at the keyboard or with the slider for laser energy at the monitor screen until only a faint cut can be seen move the laser focus up and down with the keys home and end at the keyboard or the corresponding slider for laser focus at the mon itor screen to locate ...

Страница 22: ...e 7 1 1 Simultaneous Fluorescence Observation The beam splitter in the fluorescence slide switch directly in front of the objective in the reflector slide or in the fluorescence cube is custom made The beam splitter must have a special coating suit able for the simultaneous reflection of the laser light and the fluorescence excitation wavelength as well as for the transmission of the emitted fluo ...

Страница 23: ...tion of adjusting aid for the fluorescence lamp see section 5 5 page 14 left position o k right position switch to left check shutter for FL see section 5 5 page 14 shutter open FL on display o k shutter closed open shutter check position of filter revolver filter revolver on position laser o k any other position except you have fluorescence equipment with P A L M simultaneous cutting switch to la...

Страница 24: ...ion between camera and computer S VHS plug must be plugged in framegrabber board check position of switching mirror in microscope check alignment of camera the camera must be adjusted parallel to the stage movement test this by moving the stage with the arrow keys in a slow speed g check position of laser marker Calibrate new as described in the User s Manual make sure that you are using the setti...

Страница 25: ... be impaired Dirt on surfaces of lenses or filters burnt in by laser light can not be removed any more Slightly moisten a Kleenex tissue with pure alcohol 100 or spirit and wipe the dirty parts very carefully Clean dry objectives and oculars smoothly with a cotton bud or a tooth pick padded with cotton wool Only use surgical cotton from the phar macy Remove cotton fluffs and similar by blowing wit...

Страница 26: ...0 Hz Frequency fluctuations 2 Hz Wavelength 337 nm Pulse energy 270 µJ Pulse duration 3 nsec Pulse frequency 1 30 pulses per second Beam divergence 0 3 mrad Laser control Laser control can be changed by impulse packages external by earth free foot stepper or via RS232 interface automatic permanent impulses Impulse width 0 1 ms Pulse frequency of laser control Adjustable via computer ...

Отзывы: