background image

CONTROL PANEL

 

 

. 1    Wire controller

 

Wire controller contains a LCD and 6 operational keys (as show below). It can keep memory when power off 

and be a timer.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

2. Key functions 

(1)Double-colored  indicator  light:  when  standby,  blue  light  on;  when  compressor  worked,  red  light  on;  when 

breakdown happened, red light on.    For more details, please check fault code sheet.   

(2)

Key “on/off” : power on /power off.   

(3)

Key “time adjusting”: adjust clock or set time.   

(4)

Key “down”: it’s a combined key to decrease numerical value, continuous press, then continuous decrease;

 

short press, then decrease by 1. 

 

(5)

Key “up”: it’s a combined key also, but opposite to down key.    Continuous press, then continuous increase; 

short press, then increase by 1.         

   

 

(6)

Key “confirm”: confirm previous operations   

(7)

Key “mode”: operational mode’s switch.    It’s a combined key also.   

3. Icon Meaning 

NO.   

Icon meaning 

NO.   

Icon meaning 

NO.    Icon meaning 

Clock display 

Returned    AC Temp.     

10 

Maintain icon 

11 

Lock icon 

12 

Temperature icon (Reserved) 

13 

Parameter number icon

 

14 

AC Cooling icon 

15 

Sterilization icon 

16 

AC heating icon 

17 

Sanitary hot water icon    18 

Water/ground source display 

19 

Parameter icon 

20 

Domestic  Hot  Water 

temp 

21 

Timer on icon 

22 

Timer off icon 

20 

Sterilization  days  dis-

play 

21 

Sterilization on display 

22 

Sterilization off display 

23 

Clock icon 

 

 

 

 

 
 

4

Содержание H Series

Страница 1: ...AIR TO WATER HEAT PUMP Installation and Operation Manual DC INVERTER DC INVERTER H series Only Heating series AC series Heating Cooling series HC series Mutifunctional Heating Cooling Hot water...

Страница 2: ...Content Safety Precautions Transport and storage General 2 2 2 3 4 11 12 17 19 1 Components Wired LCD Controller Error Code Installation Electric connection Test run...

Страница 3: ...ntial hazard of leakage of inflammable gas If the foundation is unstable the outdoor unit may drop and cause a casualty accident so this must be validated carefully Make sure that the foundation of in...

Страница 4: ...way valve 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 Position Position Component Component Compressor Gas liquid isolator Water inlet Drain Needle valve AH 6 AH 8 AH 11 AH 15DC 2 3 4 1 5 6 7 19 20...

Страница 5: ...hen decrease by 1 5 Key up it s a combined key also but opposite to down key Continuous press then continuous increase short press then increase by 1 6 Key confirm confirm previous operations 7 Key mo...

Страница 6: ...can change parameter according to need 3 Procedures of setting parameter change A When in settled mode the unit will operate in accordance with the factory default temperature or last modified temper...

Страница 7: ...hes and shows the original or default value default value is 10 followed by press key or to change minimum is 10 maximum no more than 99 after that press key to confirm and exit change mode If didn t...

Страница 8: ...rotection temp 100 129 2 57 check set 13 reserved 14 function parameter 0 G3 is seasonal switch valve 1 G3 is solar pre heat valve 0 check set 19 adjust fixed running rate 0 100 HZ 50HZ check set 20 R...

Страница 9: ...input status 0 DHW invalid 1 DHW valid check 09 Switch input status 0 G1 valid 1 G1 invalid check 10 high pressure swithc status 0 off 1 on check 11 overcurrent protect switch status 0 off 1 on check...

Страница 10: ...pump has water source Icon If it has timer on off setting there is timer icon to indicate 29 C4 water pump 1 run 0 stop check 30 C5 water pump 1 run 0 stop check 31 C6 water pump 1 run 0 stop check 32...

Страница 11: ...n to indicate 9 way of communication Non polarity double wire maximum running length is 100 meters and point to point connected Back view of wired controller showed below after change need be repowere...

Страница 12: ...Only for Inverter outdoor unit F3 Compressor stopped abnormally Red and shining Only for Inverter outdoor unit F4 outdoor module radiator tansducer error Red and shining Only for Inverter outdoor unit...

Страница 13: ...Method 1 12 Method 2 DHW with Room Heating Installation 1 Installationmethod...

Страница 14: ...water pump connection can be found in wiring diagram 4 Safety valve air discharge valve should be installed at the top of the circulation system for easy air discharge Air conditoning circulation can...

Страница 15: ...Application 1 Application 2 14 Installation 2 Installation with solar assistant...

Страница 16: ...ation 15 G2 G1 DHW and AC switching valve G2 Solar automatic selection valve W B D H A 5 4 Unit Dimension mm AH 6 AH 8 AH 11 AH 15 W 1091 1091 D 400 400 H 880 980 Installation 1091 400 780 A 412 412 B...

Страница 17: ...of accumulated water in rainy season In snowy areas it is important to prevent accumulated snow from blocking up the air out The recommended height is 20cm to 30cm 2 Drain ditch or other facilities sh...

Страница 18: ...s Note Electrical installation and service must be carried out under the supervision of a qualified electrician Electrical installation and wiring must be carried out in accordance with the stipulatio...

Страница 19: ...Electric connection Wiring Diagram with built inside water circulation pump Wiring Diagram No built inside water circulation pump 18...

Страница 20: ...g all usage and there is no air inside the water system Turn on the heat pump select heating domestic hot water mode check whether the unit is running properly or not the compressor will be started in...

Отзывы: