background image

UH219

UH219 Series

H I G H   P R E S S U R E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

2

1

Specifications

Housing materials:

Head and Cover:

Ductile cast iron

Tube: Steel
Cage:

Steel, with corrosive resistant plating 

Maximum operating pressure:

420 bar (6,100 psi)

Proof pressure:

630 bar (9,135 psi)

Minimum burst pressure:

1500 bar (21,750 psi)

Element burst pressure:

UE219 element 10 bard (150 psid) differential minimum

Operating temperature range:

-29°C to 120°C (-20°F to 250°F) with fluorocarbon seals for
petroleum based and specified synthetic fluids
60°C (140°F) maximum in HWCF, water-oil emulsion or 
water glycol

Bypass valve setting options:

4.5 ± 0.3 bard (65 ± 5 psid) cracking pressure
Non bypass

Seals:

Fluorocarbon
The actual operating conditions should be checked by the user
to ensure that the element, housing and all seals are
compatible with the fluid and application, and are within local
safety codes. Please contact Pall or an approved distributor if
further information is required.

2

Receipt of equipment

The filter housing, and any optional equipment, are packed
individually for assembly by the customer. Unpack carefully
and ensure optional items are not mislaid in packaging to 
be discarded.

3

General sources of information

3.1

For dimensions, operating parameters,
assembly/element part number, ordering information,
notes, performance data and specifications refer to
datasheet IMUH219EN.

3.2

This equipment has been assessed in accordance with
the guidelines laid down in the European Pressure
Directive 97/23/EC and has been classified within sound
engineering practice S.E.P. We hereby declare the
equipment meets the requirements of article 3, section
3, thus meeting the directive requirements. Under the
provisions of this directive the filter assembly is suitable
for use with group 2 fluids only.

3.3

Where under reasonably foreseeable conditions,
including external fires, the allowable limits could be
exceeded, suitable protective devices must be installed
by the customer within the connecting fluid system.

4

Installation of housing

4.1

The filter can be installed in any attitude, but for ease of
servicing, it is recommended that it be installed vertically
with the filter tube and cover pointing upwards
(UH219C) or with the filter tube and cover pointing
downwards (UH219H).

4.2

The minimum clearance required for element removal is 
as follows:
4.2.1

UH219C series (cover service): 102mm (4in) 
for length 4, 203mm (8in) for length 8, 338mm 
(13.3in) for length 13 and 508mm (20in) for 
length 20 housings.

4.2.2

UH219H series (head service): 100mm (3.9") 
for all lengths.

4.2.3

The UH219 Housing is supplied without a filter
element.  For element installation and servicing
procedures, refer to Section 7.

4.3

Threaded differential pressure devices, when fitted, must
be torque tightened to 30-33 ft/lb or 40-45 Nm. All visual
indicators must be clearly visible

NOTE: The UH219 head is supplied with two machined
differential pressure warning device ports, one fitted with a
bleed plug, the other with a plastic shipping plug. If no
differential pressure warning device is ordered, the shipping
plug must be removed and replaced with a 'B' type blanking
plug (HA9000A104Z) AND torque tightened to 40ft/lb /54Nm.
NOTE: Never place the port plug in this port without first
installing uniform size -014 O-ring in lower O-ring groove,
otherwise a small bypass flow will result, allowing contaminant
downstream of the filter element. 

4.4

Mount the filter assembly in position using two 
7/16"-14 ('A' and 'E' ports) or M10 x 1.5 ('C' and 'G'
ports) bolts in the holes on the head mounting pads.
Torque bolts to 9-19 ft/lb or 12-26 Nm.

4.5

Use a check valve downstream of the filter if there is a
possibility of reverse flow.

4.6

Install the filter housing using additional piping/valving to
allow complete filter assembly bypass if filter maintenance
is required without system shutdown. This series is not
available in a duplex or service bypass configuration.

NOTE: Piping supports should be provided as close as is
practicable to the port connections in order to minimize
external loads. This filter assembly must not be electronically
isolated from the users earthing system. This filter assembly
must be earthed by connecting the users earthing system to
one of the inlet/outlet connections.

4.7

Connect lines or hoses to housing inlet and outlet ports.

CAUTION: 
Maximum surge flow should not exceed 1.3 times
normal flow.

WARNING:
USE FITTINGS OR ADAPTORS COMPATIBLE WITH
PORTS SUPPLIED AS SHOWN BY PART NUMBER ON
NAMEPLATE AND NOTED IN DATA SHEETS: USE OF
INCORRECT FITTINGS OR ADAPTORS CAN CAUSE
FILTER HOUSING OR MANIFOLD FAILURE
RESULTING IN LOSS OF PRESSURE AND POSSIBLE
SYSTEM FAILURE OR PERSONAL INJURY.

CAUTION:
Reverse flow through filter element will cause damage.

CAUTION:
Never operate the filter unless both warning device
ports are sealed. 

Содержание UH219 Series

Страница 1: ...UH219 UH219 Series service instructions UK 60908 IMSIUH219 EN UH219 Service Instructions ENGLISH ...

Страница 2: ...required for element removal is as follows 4 2 1 UH219C series cover service 102mm 4in for length 4 203mm 8in for length 8 338mm 13 3in for length 13 and 508mm 20in for length 20 housings 4 2 2 UH219H series head service 100mm 3 9 for all lengths 4 2 3 The UH219 Housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differenti...

Страница 3: ...abels 6 Differential pressure devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 ...

Страница 4: ...the filter one and one half turns Open partially the blanking plug 6b in the filter head and drain fluid into a suitable waste receptacle This sequence may be long for high viscosity fluids Replace and torque tighten the blanking plug to 38 ft lb or 54Nm Unscrew and remove cover 3 from tube 2 counter clockwise when viewed from above It will be necessary to use a 1 socket wrench on the hexagon on t...

Страница 5: ...ltered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in u...

Страница 6: ...UH219 UH219 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 4 8 6b 3 1 Figure 2 5 7 6 Inlet Not shown on this diagram Not shown on this diagram ...

Страница 7: ...AA 4 täyskierteistä reikää syvyys AA 4 trous taraudés de profondeur AA 4 fori completamente filettati profondità AA 4 tapgaten met draad over volle diepte 4st fästhål Gänga Z Min gängdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA E16 1 1 093 2 250 7 16 14 UNC 0 87 G16 1 27 8 mm 57 2 mm M12 x 1 75 22 mm E20 11 4 1 250 2 625 1 2 13 UNC 0 75 G20 11 4 31 8 mm 66 ...

Страница 8: ...2008 Printed in England IMSIUH219 Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan T...

Отзывы: