Note: Painting of the filter housing is optional. The coating on
the filter housing is a suitable painting base. Cover the
differential pressure warning device and nameplate if painting
of the housing takes place.

4.8

Bleed the filter.

4.8.1 UH219C series (cover service): Bleed the filter by 

opening the vent plug (7) at the top of filter one and one 
half turns. Jog system and fill filter until all air bleeds 
through the plug, then torque tighten the vent plug to 
12 ft/lb or 16Nm.

4.8.2  UH219H series (head service): Bleed the filter by 

opening the blanking plug (6b) one and one-half turns. 
Jog system and fill filter until all air bleeds through the 
plug, then torque tighten the blanking plug to 40 ft/lb 
or 54 Nm. 

Pressurize system fully and check for leaks; if leaks occur 
refer to section 5.

5

Routine maintenance

5.1

Pall

filters do not normally require special attention

except for periodic monitoring of the differential pressure
warning device. Schedule replacement of filter element
every six months or sooner, and have ample supply of
spare elements available. 

5.2

If external leakage is noted, replace O-ring at leak. If
leakage persists, check sealing surfaces for scratches 
or cracks; replace any defective parts. 

5.3

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions. If 'cold start' conditions exist, 
see Section 6.2 and 6.3.

5.4

A dirty system can quickly plug a new filter element,
especially with 

Pall

high efficiency filter media. It may

require one or two initial element changes to stabilize
element life. If element life is short or differential
pressure is excessive, filter may be undersized; refer to
the sizing and selection section of the product literature
or contact your local Pall representative.

5.5

Make sure element change labels are clean and
undamaged. Replace illegible labels with the appropriate
new labels.

6

Differential pressure devices

Reference should be made to product literature for dimensions,
operating parameters, part numbering, ordering information
and specifications. 
6.1

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions. 

6.2

If visual indicator is fitted and actuates during 'cold start'
(red button extends 5mm, 3/16"), reset by depressing
the button when the normal operating temperature is
reached. If indicator actuates after resetting, replace
element. 

NOTE: Option 'P' visual indicator has thermal lockout and
manual reset. No signal below 0°C (32°F), signal above 29°C
(80°F).

6.3

If the electrical switch actuates (e.g. red light comes on)
during cold start, continue operating until the signal (red
light) goes out as system warms to normal operating
temperature. This feature can be used as 'warm up'
indication in operating procedures. If the warning signal
(red light) remains or appears when system is warm,
replace the filter element.

ENGLISH

6.4

Use of both positive indication (green light) and negative
indication (red light for dirty element) is recommended to
effectively monitor filter element life.

Electrical connections and ratings for all differential
pressure switch options:

110 VAC

=

4A (inductive),
4A (resistive)

220 VAC

=

4A (inductive),
4A (resistive)

28 VDC

=

3A (inductive),
5A (resistive)

48 VDC

=

1A (inductive),
1.5A (resistive)

125 VDC

=

0.25A (inductive),
0.5A (resistive)

Maximum inrush - 24 amps.
Underwriter’s lab. Inc. listed ratings of pressure switch
(Microswitch) options are:
4 amps at 250 VAC
0.25 amp resistive at 220 VDC
0.50 amp resistive at 110 VDC

Electrical differential pressure switch operation:

When preset differential pressure is exceeded continuity
switches from 'C' - 'A' to 'C' - 'B'.
When differential pressure decreases below the pre-set value,
continuity returns to 'C' - 'A'.

Figure 1 

- Switch Circuit Diagram

C
or black
or tag 2

CAUTION:
Failure to bleed the filter housing adequately will
increase the dissolved air content of the system fluid
which will shorten fluid life and may cause other
problems in the system.

A
or white
or tag 1

B
or red
or tag 3

LOW DIFFERENTIAL PRESSURE

HIGH DIFFERENTIAL PRESSURE

Содержание UH219 Series

Страница 1: ...UH219 UH219 Series service instructions UK 60908 IMSIUH219 EN UH219 Service Instructions ENGLISH ...

Страница 2: ...required for element removal is as follows 4 2 1 UH219C series cover service 102mm 4in for length 4 203mm 8in for length 8 338mm 13 3in for length 13 and 508mm 20in for length 20 housings 4 2 2 UH219H series head service 100mm 3 9 for all lengths 4 2 3 The UH219 Housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differenti...

Страница 3: ...abels 6 Differential pressure devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 ...

Страница 4: ...the filter one and one half turns Open partially the blanking plug 6b in the filter head and drain fluid into a suitable waste receptacle This sequence may be long for high viscosity fluids Replace and torque tighten the blanking plug to 38 ft lb or 54Nm Unscrew and remove cover 3 from tube 2 counter clockwise when viewed from above It will be necessary to use a 1 socket wrench on the hexagon on t...

Страница 5: ...ltered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in u...

Страница 6: ...UH219 UH219 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 4 8 6b 3 1 Figure 2 5 7 6 Inlet Not shown on this diagram Not shown on this diagram ...

Страница 7: ...AA 4 täyskierteistä reikää syvyys AA 4 trous taraudés de profondeur AA 4 fori completamente filettati profondità AA 4 tapgaten met draad over volle diepte 4st fästhål Gänga Z Min gängdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA E16 1 1 093 2 250 7 16 14 UNC 0 87 G16 1 27 8 mm 57 2 mm M12 x 1 75 22 mm E20 11 4 1 250 2 625 1 2 13 UNC 0 75 G20 11 4 31 8 mm 66 ...

Страница 8: ...2008 Printed in England IMSIUH219 Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan T...

Отзывы: