7.3 Checking and Changing the Oil
To check fluid:
1.
To
begin, lower gate to ground and tilt platform down.
2.
Remove the cover from the Hydraulic Power Unit enclosure. The cover is hinged and opens to right.
3.
The level of the oil should be 2
“ from the top of the oil reservoir when the platform is tilted down at
ground level. If fluid is required, use a recommended fluid from the table below.
Metal Brace
Remove
Hardware
Pull Out
Pump & Motor
Pump and Motor Located Inside Mount Frame on the Right Side.
To change fluid:
1. Unscrew the Oil Drain Bolt and let the fluid drain out of the reservoir into an approved cointainer.
When reservoir is empty fill the reservoir up 2
“ from the top of the reservoir. Change oil at least once
a year, preferable in the fall before the weather gets cold.
2. Place the cover back on to the Hydraulic Power Unit enclosure.
2"
Oil Drain Bolt
Oil Filler
When changing or adding fluids, it is highly recommended to use alternatives fluid brands and types listed
below:
Alternative Fluids
Temperature Range
Fluid Brand
30° to 150° F
EXXON UNIVIS J26
MOBIL DTE 13M
CHEVRON AW MV32
ROSEMEAD MV 150 (32)
-50° to 150° F
HYDREX MV ARCTIC 15
MOBILE DTE 11
SHELL AERO FLUID 4/41
SHELL TELLUS 15
Extreme Cold Temperature
MIL H5606 (Military Spec.)