ILP 25/33 Installation Manual
Rev. 1.4
- 48 -
13.2
Cable Routing
1. The use of wire loom is highly recommended to protect and facilitate cable routing. Wire loom not
supplied.
2. Route all cables along the wooden spacer and through the outside of the U-bolts or on the inside
part of the channel.
3. Secure the wire along the wooded spacer with insulated cable clamps.
Do not tie electrical cables along with hoses.
Body
Long
Sill
Wooden
Spacer(s)
Chassis
Frame
U-Bolt
Cable Routed
Outside of U-Bolts
w/Slack
Insulated
Cable
Clamps
Cable Routed
on Inside of Channel
13.3
Connecting Power to Liftgate
1. Remove the cover from the Hydraulic Power Unit enclosure by removing the two wing nuts.
Insert one end of the power cable through the indicated opening on the hydraulic power unit
enclosure. Remove the nut from the solenoid post and attach the power cable to the post. Torque
the nut to 3 ft./lbs. Route the other end of the power cable to the circuit breaker by the batteries.
NOTE: Do not disconnect any of the pre-installed wires on the solenoid or motor.
Feed Power Cable
Through Here
Wing Nuts
Solenoid
To
Circuit
Breaker
Power
Cable
Solenoid
Post
Torque: 3 ft/lbs [4 Nm]
Hydraulic Power
Unit Enclosure