Following steps 8-9, click SET and wait until
the setting completion window appears.
STEP 10
Restart the charger; This can be achieved by
switching off the mains supply to it and waiting
five seconds before turning it back
STEP 11
•
For other settings (such as OCPP etc.), please contact Lewden Ltd
7.
6
Error and Warning Messages
Status
Blue
Green
Red
Remark
Input over voltage
(OVP) >275V
-
1 flashes followed
by 3 second pause
Automatic
Recovery
Input under voltage
(UVP) <160V
-
2 flashes followed
by 3 second pause
Automatic
Recovery
Output over current
(OCP) >36.8A
-
3 flashes followed
by 3 second pause
Automatic
Recovery
Over temp.
(OTP) >90 deg C
-
4 flashes followed
by 3 second pause
Automatic
Recovery
RCD Abnormal
-
5 flashes followed
by 3 second pause
Automatic
Recovery
Ground Monitor
Interrupter
-
6 flashes followed
by 3 second pause
Automatic
Recovery
Control Pilot Fault
-
Flicker
Automatic
Recovery
Micro control unit
(MCU) Self-Test Fail
-
Constantly bright
Contact Customer
Services
RCD Self-Test Fail
-
Constantly bright
Contact Customer
Services
Relay Self-Test Fail
-
Constantly bright
Contact Customer
Services
RCD Self-Test Stop
Charging
-
Constantly
bright
Constantly bright
Contact Customer
Services
Output OCP - Stop
Charging
Constantly
bright
Constantly bright
Contact Customer
Services
Over temp.
(OTP) >100 deg C
Flicker
Flicker
Constantly bright
Contact Customer
Services