A
Dip switch
Rotary switch
B
A
B
1. The default setting for all countries is 32A, except for Japan which is 30A
2. Reducing the maximum output current of the charger will increase the charging
time of the connected vehicle.
Notes
Switch
Setting
Number
0
1
2
3
4
5
6
7
8,9
A
B~E
F
Maximum
Output
Current
Test
Mode
6A
8A
10A 13A 16A 20A 25A 32A 30A Invalid
Setting
Slave
Mode
b) Maximum Output Current
To serve installations which do not have a suitable supply capacity to enable the
Incorporation of a charging system operating at 32A, the AC charger can support
different values of maximum output current through the setting of an integral rotary
switch.
Settings are detailed in the table below.
•
Before setting the rotary switch, ensure that the power
supply to the charger has been isolated.
•
Use a non-conductive object to set the rotary switch.
A S P E N Series - User Manual
13