![Palazzetti WILMA Скачать руководство пользователя страница 19](http://html2.mh-extra.com/html/palazzetti/wilma/wilma_use-and-function_3540622019.webp)
ENGLISH
1.1.2 Description of the menus
ICON
FUNCTION
DESCRIPTION
VALUES
Power
Stove output setting
1..5
Fan
Setting of the air fan speed.
1..5; Auto; Hi
Temperature
Displays the
probe*
temperature reading and is used to set the desired
temperature.
*con
¿
g.1:
water
probe; con
¿
g.2: room probe; con
¿
g. 3-4: external/tank probe.
con
¿
g.1: 55..
C
con
¿
g.2: 1
.. 4
C
con
¿
g.3-4: 5
..75
C
Fuel
Not used
Timer
Enables or disables the timer. When enabled, the icon
will be displayed steady
(not
À
ashing)
ON - OFF
ICON
FUNCTION
SUBMENU
DESCRIPTION
VALUES
Setup
[1]
Weekly timer
Assigns the programs (max 3) to the different days of the week
[d1] ... [d7]
[2]
Programs
Program setting menu
[P1] ... [P6]
[3]
Time / date
Time and date setting
[4]
Hours remaining
Displays the number of hours remaining until recommended
maintenance. When “Hi” is displayed, the remaining time exceeds
999 hours.
[5]
System information
Displays the current software version
[6]
Water temperature
It allows to set the desired temperature for the water supply
(only in con
¿
guration 2-5).
6
...
C
[7]
Eco function
Enables or disables Eco Mode, in which the stove automatically
switches off and on based on room temperature (only in
con
¿
guration 2-5).
OFF; Eco
[8]
Restart delta
Is the number of degrees centigrade below the switch-off
temperature at which the stove switches on again automatically
(except in con
¿
guration 1).
,5 ... 5,
C
... 4
C
[9]
Frost protection temperature
Minimum temperature below which the stove switches on
(except in con
¿
guration 1).
OFF; 3 ... 2
C
OFF; 3 ... 5
C
[10]
Lock keypad
Disables the buttons on the keypad
OFF; Lo; Hi
[11]
Display brightness
Sets display brightness
OFF; 1 ... 5
[12]
Display mode
Sets how the data is displayed
OFF; 1 ... 4
[13]
Buzzer volume
Sets the buzzer volume
OFF; 1 ... 5
[14]
Combustion
Three different types of combustion can be set
1 ... 3
[30]
Installer menu
Sets/displays the stove configuration
PWD: “54”
[31]
Manual auger load
Manual activation of the pellet load system
PWD: “54”
[33]
Pump power
Menu relating to the service centre
PWD: “54”
[34]
Enable/Disable
Menu di competenza del centro di assistenza
PWD: “54”
[40]
pump modulation
Menu relating to the service centre
Submenus
[30]
and
[40]
in the Setup menu are password-protected and reserved for service centre personnel.