3.
ELECTRICAL CONNECTIONS
FUSE
T1,6A
12 11 10 9
S1
S2
1
5 6 7
2 3 4
LINEA
230Vac
L-
O
N
L
N
8
N
VENT
230Vac
SERV
IN
SCI
All the control Outputs and probe Inputs are
controlled automatically according to the
type/diagram of the chosen Installation.
Therefore, for the electrical connections
you MUST refer to chapter 8 and the subse-
quent paragraphs of the Installation Diagrams.
Fig. 2 - Electric connections
Initials
Terminals
Device
Charateristics
INP
U
TS
LINE
1 – 2
Mains Power Sup-
ply
230 Vac 50 Hz ± 10%
IN SCI
3 – 4
Spark Consent
Input 230 Vac 50 Hz ± 10%
S1
9 – 10
Room Temperatu-
re Probe /
Room Temp. Ther-
mostat
Range of operation: -10°C ÷ 180
°C
NTC 100K Misura: -10 ÷ 300 °C
± 1°C
S2
11 – 12
Room Temperatu-
re Probe /
Room Temp. Ther-
mostat
Range of operation: -10°C ÷ 125
°C
NTC 10K Misura: -10 ÷ 110 °C ±
1°C
O
UT
P
UT
S
VENT
5 – 6
Fan
230 Vac 0,8A
SERV
7 - 8
Service Output
Free contacts: COM. (7) - N.O.
(8)