8
5.7
PROBES DISPLAY
The display currently shows the value read from the
S1 Probe
if
P17 = 1
Through a simple click of the
K2
key, the temperature of the
S2 Probe
is displayed (LED flashes).
You can exit from this display via the
K1
key, scrolling all probes with the
K2
key, or automatically after 10 seconds.
If the reading of the probes is lower than the minimum range of the sensor, this message displays the message
Lo
If the reading of the probes is higher than the maximum range of the sensor, this message displays the message
Hi
5.8
SERVICE OUTPUT
The SERVICE Output is programmable from the Installer MENU of parameter
P02
:
P02 = 0 DISABLED
: the output does not work
P02 = 1 THERMOSTAT
: the output is active if the temperature of the
S1 Probe
is greater than the
E07
thermostat
P02 = 2 GRILL
: pressing the
K3
button for 3 seconds you can turn on or turn off the output
P02 = 3 DAMPER
: the output manages a damper for the adjustment of the combustion air
P02 = 4 SPARK
: the output manages the spark control
The functions
THERMOSTAT AND DAMPER
are disabled in the case of
P17 = 1
.
5.9
DAMPER [P17 = 1]
The Damper is enabled if the parameter
P02 = 3
If the output is Active (ON) the Damper is Open, if the output is off (OFF) the Damper is Closed.
The Damper is Open until the temperature of the
S1 Probe
is lesser than the
E06
thermostat. It is closed when that
thermostat is exceeded.
If
P12 = 1
is enabled, the
Manual Start
function:
If the Temperature of
S1
is lower than
E05
, the Damper is Closed. In the ignition phase of the Stove, pressing the
K3
for 3
seconds, it forces the manual opening of the Damper (the LED
flashes). When the temperature again drops below the
thermostat
E05
, after the
t06
time has passed, the Damper Automatically closes.
5.10
SPARK Function
The Damper is enabled if the parameter
P02 = 4
By pressing the
K1
key the output relative to the Spark kit is activated: the device displays the writing '
Sci
' flashing for 2
sec. This indication remains visible until the firebox has turned on.
5.11
INPUT S2 CONFIGURATION
Using parameter
P01
you can enable the following connection managers:
P01 = 0,
input
S2
=
DISABLED
P01 = 1,
input
S2
=
ROOM TEMP PROBE
P01 = 2,
input
S2
=
ROOM TEMP THERMOSTAT
5.12
SENSOR PROBE/ROOM TEMP THERMOSTAT
Using parameter
P01
it is possible to enable the management of the
ROOM TEMPERATURE
Probe/Thermostat
If the Temperature of the Room Temperature Probe is greater than the thermostat
b01
or the Contact of the External
Temperature Thermostat is
Open
(the LED flashes)
•
The Fan is switched Off
•
The Damper is Closed if P02 = 3
5.13
FAN STARTING FUNCTION
This operation allows the Fan to operate at Maximum Speed for a programmable time (
t08
), every time that it has to start
from a standstill. After the time has lapsed the Fan will resume to programmed speed.
To disable the Fan Starting function, programme the time
t08
to t
0 seconds
.
6.
MENU
6.1
MAIN MENU
It is accessible by pressing the
K2
button for 3 seconds
Always with the
K2
key, it scrolls through the various parameters, indicated by the flashing of the associated LED.
With the keys
K3
and
K4
you can modify the value of the parameters.
Press the
K2
key to save the new value or wait 10 seconds.
Press the
K1
key to exit without saving.
LED
Description
Code
Min
Set
Max
U.O.M.
MANUAL Operation
MANU
MANU
AUTO
PROP
-
AUTOMATIC Operation
AUTO
PROPORTIONAL Operation
PROP
Room Temp. Thermostat
b01
5
20
50
[°C]