14
GHI
Type infrared ceramic heaters
User’s Manual
ATTENTION! In case operational circumstances of appliance (atmosphere is contaminated with cor
-
rosive substances, dirt etc.) need it, then supervision and cleaning may have done more often! The
main reason of this that the settled dirt on the radiant tubes can damage the efficiency of it and load
the tubes hereby loading the suspensions of it significantly!
Attention! By disambeling or modiffying the unit please turn to our Service center.
(PAKOLE Trade ltd. HUNGARY, 8000, Székesfehérvár, Börgöndi út 8-10. , e-mail: [email protected],
tel.: +36 22/316-484)
Avoiding to do so may result in death, injury or material damage.
Gas change
Tel.:22/316-484 Fax.: 22/316-074
a) Check the statement of reflectors and clean them if it is necessary. Clean them by a soft cloth or a diluted detergent.
b) Check, if catalytic grid made of heat-resistant steel placed in front of ceramic plates touches ceramic plates or not. In case it
touches it at some places, then drag it away from ceramics by a thin bent steel wire.
c) Check ceramic plates. Blow them sometimes through by compressed air when it is switched off and cool enough.
d) Check, if ceramic plates are broken or not by a survey. There is a bright line dur-ing glowing position at a broken appliance,
which line indicates the place of breaking.
e) Check mountings screw fastenings at fixing frame by survey.
It is advisable to make a maintenance contract for the proper maintenance or call our qualified service department for regular mainte
-
nance.
Maintenance supervisions by the customer
all kinds of interventions for which dismantling of device is necessary
a) Supervision of nozzle pressure (at the secondary outlet of solenoid valve)
b) Supervision of electrical connection
c) Supervision of ignition module and spark interval
d) Supervision of thermo-element and thermo-valve at manually ignited appliance
Maintenance supervisions by a qualified service department
In case you would like to operate your appliance by another type of gas (for example by Natural Gas
or Propane instead of butane gas), then turn to the local authorised representative or a qualified
service department.
ATTENTION! This operation can be made just the qualified service department or specialist, who is
entrusted by the manufacturer!