background image

Section 150-219-100-02

December 22, 1997

Page 2

HDU-217/219 and

 

HCC-239 List

 

1

The HDU-217 and HDU-219 HiGain doubler units (HDUs) extend the
delivery of fractional T1 High-Capacity Digital Service (HCDS) to
customers over metallic cable pairs.  The HDUs are installed between
a HLU-D41 List 2D (HiGain line unit) and a HRU-512 (HiGain
remote unit).

The HDU-217 and HDU-219 allow 784 Kbps transmission over twice
the normal Carrier Serving Area (CSA) range to 24,000 feet
(7.315 km) of 24 AWG or 18,000 feet (5.486 km) of 26 AWG copper
loops.  Two doubler units can triple the CSA range to 36,000 feet
(10.97 km) of 24 AWG loops or to 27,000 feet (8.22 km) of 26 AWG
loops.

The HCC-239 (HiGain Cut-through Card) is provided with the
HDU-219.  The HDU-219 mounts into two adjacent slots of a
standard 239 mini-T1 repeater apparatus case and blocks one slot.
The HCC-239 allows pair cut-through on the blocked repeater slot.
The HDU-217 doubler units occupy one slot of the original DDS or
ISDN repeater apparatus case—these slots are about twice the width
of a 239 T1 repeater.  All HiGain modules comply with the applicable
requirements of Network Equipment Building System (NEBS)
Generic Equipment requirements TR-TSY-000063 and Transport
System Generic Requirements TSGR TR-TSY-000499.

About the Mini Doubler

HiGain uses PairGain’s Two-Binary, One-Quaternary (2B1Q) High-
bit-rate Digital Subscriber Line (HDSL) transceiver systems to
establish a full-duplex, 784 kbps data channel between the line units
and the remote units.  Each HDU-217 and HDU-219 increases the
maximum range of a new doubler circuit by approximately 12,000
feet (3.66 km) for 24 AWG cable or 9,000 feet (2.74 km) for 26 AWG
cable.

A block diagram of the HDU-217 and HDU-219 with pinouts is
shown in Figure 2.  The HDU-217 and HDU-219 power supplies use
the 200 Vdc power feed voltage received on the HDSL pair to
produce the +5 Vdc and –5 Vdc required by the HDU-217 and
HDU-219 electronics.  The power feed continues through the HDSL
output pair to a second doubler or to the remote HRU-512.

Содержание HiGain HDU-217

Страница 1: ...1 T1R5AS0EAA HDU 219 1 150 1501 01 T1R5AR0EAA HCC 239 1 150 1550 01 N A PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES TECHNICAL PRACTICE SECTION 150 219 100 02 Revision History of this practice Revis...

Страница 2: ...ies Inc Information contained in this document is company private to PairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written con...

Страница 3: ...________________6 Inspecting Your Shipment 6 Installing the Mini Doubler 6 Installing and Removing the Cut Through Card 13 Locating Doubler Unit Enclosures 15 TESTING THE UNIT ________________________...

Страница 4: ...7 219 and HCC 239 List 1 USING THIS TECHNICAL PRACTICE Two types of messages identified by icons appear in the text A note informs you of special circumstances Cautions indicate the possibility of dam...

Страница 5: ...ingle pair doubler units in mini repeater packages Each extends the range of a HiGain repeaterless fractional T1 transmission system HDU 217 and HDU 219 HiGain Mini Doubler features include Figure1 Fr...

Страница 6: ...oubler units occupy one slot of the original DDS or ISDN repeater apparatus case these slots are about twice the width of a 239 T1 repeater All HiGain modules comply with the applicable requirements o...

Страница 7: ...der group A list of HDSL signal cable losses for various cable gauges at 196 kHz and 135 Ohms is shown in Table 1 The table applies to the HDSL cable pair between the HLU D41 and the HDU as well as be...

Страница 8: ...s Line Output DC Resistive Signature 25 Ohms Startup Time per span 15 seconds typical 30 seconds maximum Line Clock Rate Internal Stratum 4 clock Maximum Power Consumption 3 6 watts Maximum Provisioni...

Страница 9: ...res Complies with Section 10 2 1 3 of TA NWT 001210 Operating Elevation 200 feet 60 96 m below sea level to 13 000 feet 3 96 km above sea level Dimensions HDU 217 Single slot of original DDS IDSN Repe...

Страница 10: ...g Proper connections Grounding Line and local power All wiring external to the product s should follow the provisions of the current edition of the National Electrical Code Once the HDU 217 or HDU 219...

Страница 11: ...on Full solar load is equal to the maximum sunlight exposure as defined in TR TSY 000057 The capacities listed for the indoor enclosures in Table 1 assume no solar load The capacities listed for the o...

Страница 12: ...n be installed in the same apparatus case with the doubler unit If this method is used the maximum number of doubler units that can occupy the same case with the standard repeaters must be reduced by...

Страница 13: ...llow cover which cannot accommodate the HDU 219 length However the 818 case can be used if the shallow cover is replaced by the deeper cover of the 819 apparatus case The doubler unit capacity deploym...

Страница 14: ...819 4 per chamber 8 total 25 1 5 11 14 15 18 22 25 AT T Outdoor 841 cabinet 27A B C or D shelf 8 per shelf 32 total 25 per shelf 100 total 1 5 11 14 15 18 22 25 AT T Outdoor cabinet 809 5 12 1 5 8 10...

Страница 15: ...12 1 4 7 10 7130 25FP 6 25 1 4 7 10 18 28 Requires removing the metal slot separator Slot numbers refer to the slots into which a doubler unit may be inserted to access its four network cable pairs 6...

Страница 16: ...7 Doubler Capacity DDS Repeater Capacity Recommended Slot Assignment for Maximum Capacity SPC Outdoor canister pole wall mount 7130 0656 2 6 1 6 or 3 4 7130 0856 4 8 1 4 7 16 7130 1656 6 16 1 4 7 10 1...

Страница 17: ...9 installation may be purchased from PairGain A package of 25 HCC 239 cut through cards PairGain part number 150 1550 01 is also available if this cut through feature is needed in other doubler instal...

Страница 18: ...ollows 1 Grip the end of the tool and insert the tool into the slot cavity containing the HCC 239 card 2 Carefully insert the tool hook into the removal hole in the card 3 Align the hook along the ope...

Страница 19: ...is also 35 dB 2 If rule 1 is not applicable no customers 105 dB away then try to make all spans the same electrical length same 196 kHz loss This minimizes the maximum span loss and assures maximum o...

Страница 20: ...module Solid green HDSL frame synchronization has been achieved between the HDU and both the upstream and downstream modules Flashing red once per second HDSL Cyclic Redundancy Check CRC error has occ...

Страница 21: ...in the doubler The loopbacks can be initiated from the HLU RS 232 Craft port the HLU front panel buttons or from a family of Special Loopback SPLP in band loopback commands The loopback command set i...

Страница 22: ...Section 150 219 100 02 December 22 1997 Page 18 HDU 217 219 and HCC 239 List 1 Figure 5 HiGain Loopbacks...

Страница 23: ...100 V to 200 Vdc between pins 5 or 6 and 8 or 9 This voltage peaks every 15 seconds as the HLU powers up If less than 130 Vdc is present check the cabling or the HLU Only the line units mentioned in t...

Страница 24: ...ance is handled by an on duty Customer Service Engineer through a callback process This process normally results in a callback within 30 minutes of initiating the request In addition PairGain maintain...

Страница 25: ...original shipment given proper installation and regular maintenance PairGain will repair or replace any unit without cost during this period if the unit is found to be defective for any reason other...

Страница 26: ...ough Card HCDS High Capacity Digital Service HDSL High bit rate Digital Subscriber Line HDU HiGain Doubler Unit HLU HiGain Line Unit HRU HiGain Remote Unit ISDN Integrated Services Digital Network KBP...

Страница 27: ...December 22 1997 Section 150 219 100 02 HDU 217 219 and HCC 239 List 1 Page 23...

Страница 28: ......

Отзывы: