Section 150-319-254
Revision 02
Page 16
TABLE 5. ELU-319 STATUS MENU DEFINITIONS
Message
Full Name
Description
ALARMS
NONE
No Alarms
LLOS
Local Loss of Signal
No signal from local G.703 interface.
RLOS
Remote Loss of Signal
No signal from remote G.703 interface.
LOSW 1 (2)
Loss of (HDSL) Sync Word
1 or 2
HDSL LOOP 1 or 2 has lost frame sync.
H1ES
HDSL Loop 1 Errored
Second
The number of Loop 1’s Errored Seconds has exceeded the user-
selected Errored Seconds threshold.
H2ES
HDSL Loop 2 Errored
Second
The number of Loop 2’s Errored Seconds has exceeded the user-
selected Errored Seconds threshold.
G.703
G.703
G.703 input BPVs have exceeded the user selected ES threshold.
MAL1
Margin Alarm
(HDSL Loop 1)
The margin on HDSL Loop 1 dropped below the Margin Alarm
Threshold (1 to 15). Setting the threshold to 0 (zero) inhibits the
alarm.
MAL2
Margin Alarm
(HDSL Loop 2)
The margin on HDSL Loop 2 dropped below the user Margin
Alarm Threshold (1 to 15). Setting the threshold to 0 (zero)
inhibits the alarm.
ACO
Alarm Cut Off
AM Alarm cut-off is in effect.
LAIS
Local Alarm
Indicating Signal
Indicates an AIS (all 1’s) pattern is being transmitted from the
local G.703 output port.
RAIS
Remote Alarm Indicating
Signal
Indicates an AIS (all 1’s) pattern is being transmitted from the
remote G.703 output port.
LOOPBACKS
NREM
Network Remote Loopback
Loopback at ERU-412 (remote) towards network initiated from
ERU-412 front panel pushbutton, or maintenance terminal, or by
pressing both the MODE and SEL pushbuttons on the ELU-319
front panel. See Figure 5.
NLOC
Network Local Loopback
Loopback at ELU-319 (local) towards network by pressing both the
MODE and SEL pushbuttons on the ELU-319 front panel. See
Figure 5.
CLOC
Customer Local Loopback
Loopback at ERU-412 (local) towards customer interface (CI)
initiated from the maintenance terminal or by pressing both the
MODE and SEL pushbuttons on the ELU-319 front panel. See
Figure 5.
CHREV
Channels Reversed
Channel (loop) 1 and 2 HDSL pairs are reversed at the ERU-412
line input ports.
CREM
Customer Remote
Loopback
Loopback at ELU-319 towards customer interface (CI) initiated
from the maintenance terminal or by pressing both MODE and SEL
pushbuttons on the ELU-319 front panel. See Figure 5.
Содержание 150-1236-54
Страница 19: ...Section 150 319 254 Revision 02 Page 19 Figure 6 Main Menu Figure 7 Span Status Display no Doubler...
Страница 20: ...Section 150 319 254 Revision 02 Page 20 Figure 8 Set Clock Menu Figure 9 System Settings Menu...
Страница 32: ...Section 150 319 254 Revision 02 Page 32 Figure 15 Main Menu Figure 16 Span Status Display no Doublers...
Страница 34: ...Section 150 319 254 Revision 02 Page 34 Figure 19 Span 3 Status Display two Doublers Figure 20 Set Clock Menu...
Страница 35: ...Section 150 319 254 Revision 02 Page 35 Figure 21 System Settings Menu Figure 22 Loopback Menu one Doubler...
Страница 36: ...Section 150 319 254 Revision 02 Page 36 Figure 23 Performance Data Span 1 Figure 24 Performance Data Span 2...
Страница 37: ...Section 150 319 254 Revision 02 Page 37 Figure 25 Performance Data Span 3 Figure 26 Performance History Span 1...
Страница 39: ...Section 150 319 254 Revision 02 Page 39 Figure 29 Alarm History Span 1 Figure 30 Alarm History Span 2...