9
Bulk
Absorption
Float
Pulse
Battery Range
Types of Batteries
Deep Cycle
VSR Model-Default
(Ignition Override Not Connected)
Low Voltage Model- Ignition
Override cable connected to
ignition switch (Ignition on)
EMC
IP Rating
Equalisation
(Calcium mode only)
3.8A Constant Current Charge
up to 16V then hold 1 hour
(5 hours timeout)
Turn on
13.2V
Turn on
12.2V
Turn off
12.8V
Turn off
10.5V
Turn on
26.4V
Turn on
24.4V
Turn off
25.2V
Turn off
23.2V
EN 61000, EN 55014 Class B
IP67
25A up to
14.1V (GEL)
14.4(AGM)
14.7V(WET)
15.4V(CALCIUM)
14.4V(LITHIUM)
50A up to
14.1V (GEL)
14.4(AGM)
14.7V(WET)
15.4V(CALCIUM)
14.4V(LITHIUM)
Constant voltage until
current drops to 3.8A
13.7V Also with pulse feature (GEL, AGM, WET, CALCIUM)
13.6V Also with pulse feature (LITHIUM)
12.6V- 14.1V, 25-2.5A(GEL)
12.6V- 14.4V, 25-2.5A(AGM)
12.6V- 14.7V, 25-2.5A(WEL)
12.6V- 15.4V, 25-2.5A(CALCIUM )
12.6V- 14.4V,25-2.5A(LITHIUM)
12.6V- 14.1V, 50-5A(GEL)
12.6V- 14.4V, 50-5A (AGM)
12.6V- 14.7V, 50-5A(WEL)
12.6V- 15.4V, 50-5A(CALCIUM )
12.6V- 14.4V, 50-5A(LITHIUM)
Constant voltage until
current drops to 7.5A
7.5A Constant Current Charge
up to 16V then hold 1 hour
(5 hours timeout)
GEL, AGM, WET,
CALCIUM
LITHIUM
GEL, AGM, WET,
CALCIUM
LITHIUM
75-300Ah 50-250Ah 150-600Ah 100-500Ah
Types of Batteries
All types of 12V lead-acid batteries
(GEL, AGM, WET, CALCIUM) and LITHIUM batteries
Operating Model
12V Vehicle 24V Vehicle
Standards
Time delay function
There is a 30 second delay before charger will cut in or cut out.