14
11. SELECTION OF AUXILIARY BATTERY TYPE
Heatshrink
Temperature
Sensing Cable
(8). Cut/remove Temperature Sensing cable if temperature compensated
battery charging is not needed. Use supplied heatshrink to insulate the open
end of Temperature Sensing cable.
If temperature compensated charging is required, attach the ring terminal of
the Temperature Sensing cable to the auxiliary battery negative terminal. For
best results, attach the ring terminal to the auxiliary battery plastic surface
with thermal conductive adhesive such as 3M TC-2810 or equivalent.
Press the Mode button on the front panel until all Battery Chemistry LEDs are
flashing. There are 5 battery chemistries available: Gel, AGM, Wet, Calcium
and Lithium -ion with LiFePO Keep pressing the button momentarily until the
4.
Battery Chemistry LED you want is flashing. After you release the button, your
selection is entered and saved. Your selection will be restored automatically
even after the SVDC1225 / SVDC1250 is fully disconnected and reconnected.
The default Battery Chemistry is AGM.