77/78
06/02/2008
1.00
DIB: connection to the ice builder
Introduction
You have to connect the milk cooling tank to an ice builder by means of a supply pipe and an outlet pipe.
Connection at the milk cooling tank
You will find the connection points for the supply and outlet pipe(s) of ice water at the backside of the milk
cooling tank.
On small tanks, equipped with only 1 heat
exchanger, you will find 1 connection point on the
right hand side and one on the left hand side. It is not
important which one is used as inlet.
On big tanks, equipped with 2 heat exchangers, you
will find 2 inlet and 2 outlets. The 2 heat exchangers
each have to be connected to an ice water pump.
OD
Reduction G - glue
Reduction glue
connection
Ø
Ref.
Ø
Ref.
OM/DIB
G ¾"
¾"-25/32
128655
32F-32F
23826
REM/DIB
G 1¼"
1¼"-40/50
128656
40M-32F
26466
LEM/DIB
G 1½"
1½"-50/63
128657
50M-32F
27824
Connection at the ice builder
Check the installation manual of your ice builder.
Attention
See to it that all connections are leakproof.
Only use copper, PVC or stainless steel pipes.
OUT
OUT
IN
IN