Section 5
LABELING UNIT
-
19
-
English
F
412
0501
00.fm
ID
M
version:
Module 40/60/90/120
2 -Press the UP and DOWN keys (or the A+UP,
A+DOWN combinations) to specify the value of the
password.
3 -Confirm the password with the Enter key.
4 -If the password is correct, the display will show
“C00” on the first line, which indicates the
configuration parameter number, and a short
message on the second line that describes the
meaning of the parameter in question.
5 -Press the UP and DOWN keys to scroll through the
list of parameters; the display will show each
parameter according to its number and the
corresponding description.
6 -When the parameter that you want to change
appears, press the Enter key: the first line of the
display will show the current value of the
parameter concerned.
7 -Using the UP, DOWN, A+UP, A+DOWN keys, set
the required value and then confirm the new
setting by pressing the Enter key.
8 -After setting the parameter, you can go on to set
other parameters by starting again from item 5, or
you can abandon the procedure by pressing the P
key.
The parameters accessible to the user are:
C00 – Size code
This is the number associated with the parameters for
a given size. When you change the size code, the
parameters specified for the size are saved in the
memory; they can subsequently be changed. Values
from 1 to 10 are allowable.
C01 – Language code
This parameter is not used in the more recent
releases.
C02 - Password
This is the code needed for access to the parameter
setting procedures. On delivery, the C02 parameter is
set on a value of 1.
C03 – Ready to start?
If the parameter setting is NO, the machine starts in
pause mode when it is switched on; if the parameter is
set on YES (the default setting), the machine starts in
a ready state when it is switched on. Use the UP and
DOWN keys to change the setting from YES to NO and
vice versa.
Setting the size-related operating parameters
The size parameters are specified in much the same
way as the configuration parameters; the password to
input is the same.
The size parameters are correlated with a size number;
the machine can store 10 different sets of parameters
associated with ten different sizes. When you recall a
certain size, the machine automatically loads the
parameters associated with it, thereby avoiding the
need to reset all the parameters every time. For the
size-changing procedure, see the previous paragraph.
To set these parameters, follow the procedure outlined
below.
1 -Press the P key: the display shows the message
“PASSWORD” followed by the number 0.
2 -Press the UP and DOWN keys (or the A+UP,
A+DOWN combinations) to specify the value of the
password.
3 -Confirm the password by pressing the Enter key.
4 -If the password is correct, the display shows
“P00Fxx” on the first line (which means: parameter
0 for size xx), and a short message on the second
line that describes the meaning of the parameter in
question.
5 -Press the UP and DOWN keys to scroll through the
list of parameters; the display will show each
parameter according to its number and a
corresponding description.
6 -When the parameter that you want to change
appears, press the Enter key: the first line of the
display will show the current value of the parameter
concerned.
7 -Using the UP, DOWN, A+UP, A+DOWN keys, set
the required value and then confirm the new setting
by pressing the Enter key.
8 -After setting the parameter, you can go on to set
other parameters by starting again from item 5, or
you can abandon the procedure by pressing the P
key.
The parameters accessible to the user are:
P00 – Speed
The meaning of this parameter depends on the method
used to adjust the speed setting; the machine can be
configured to operate in synchronized mode (with the
encoder) or in constant speed mode (without the
encoder).