The SNMP Traps table should appear as follows.
Figure 125: SNMP Traps Table (Example)
10.1.3
Configuring Management for PL-1000RO B
When configuring the management for PL-1000RO B, make sure that:
•
Different IP addresses are assigned to each MNG port in the remote and local
nodes.
•
The MNG ports of the remote and local PL-1000RO nodes should be in the
same subnet.
To configure the management for PL-1000RO B:
1.
Click
Configuration
.
2.
Click
System
.
The System Configuration window opens.
3.
Click the
IP
tab.
The IP tab opens displaying the IP Address and Static Routing configuration
(see
4.
Set the IP address of the OSC interfaces manually. In the
IP Addresses
section, fill in the fields as follows:
LAN IP Address
: 192.168.1.111
LAN Subnet Mask
: 255.255.0.0
Default Gateway
: 11.0.0.111
OSC/In-band IP Address
: 11.0.0.96
OSC/In-band Subnet Mask
: 255.255.0.0
N
OTE
:
This example assumes that you are working in
Dual Network
mode.
5.
Click
Apply
.