PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off
top and right edge. Left side of page extends to 9.25 inches.
JP5 (SCA Remote/Delay Start)
Caution:
Jumper configuration to be performed by
qualified service personnel only.
The spin-up of the drive slots is determined by adding
jumpers to JP5. JP5 is a two position dual-row header.
Position 1 & 2 control the “Delayed_Start” signal and
position 3 & 4 control the “Remote_Start” signal.
JP5
REMOTE
DELAY
1
2
4 3
Pins 1 and 2
Pins 3 and 4
Drive Spinup Mode
ON
ON
Motor spins up only on SCSI “start”
commands.
ON
OFF
Motor spins up after a delay of 12
(may vary depending on drive type)
seconds times the numeric SCSI ID
setting of the associated drive.
OFF
ON
Motor spins up only on SCSI “start”
commands.
OFF
OFF
Motor spins up at DC power on.