Connect one end of a 1 meter jumper cable to the
Channel 0 connector on the upper or right side I/O
Interface card in the master cabinet.
11
Connect the other end of the 1 meter jumper cable to
the Channel 1 connector on the upper or right side
1-channel Ultra Extender card installed in the slave
#2 cabinet.
12
Connect one end of the second 25 meter data cable to
the Channel #2 connector on the differential host
adapter.
13
Connect the other end of the data cable to the
Channel 1 connector on the lower or left side 2-
channel Differential Converter card.
14
Connect one end of a second 1 meter jumper cable to
the Channel 1 connector on the upper or right side
I/O Interface card in the master cabinet.
15
Connect the other end of the second 1 meter jumper
cable to the Channel 1 connector on the upper or
right side 1-channel Ultra Extender card installed in
the slave #1 cabinet.
Note: SCSI termination is automatic and requires no
user configuration.
16
Turn on the power to the DEU.
17
After the power-on self-test has completed, HDD
Status and Channel Mode LEDs will be solid green.
18
Access the Options menu on the Operator Control
Panel and choose the SAFTE CHAIN ID selection.
Refer to “SAFTE CHAIN ID” earlier in this Guide.
19
After setting the cabinet identifications you must
power cycle the subsystems. Observe normal power
cycling precautions by waiting a minimum of five
seconds before adding power again.
This will reset the SCSI IDs to a default setting that
prevents a SCSI ID conflict under normal conditions,
refer to “Default Configurations” later in this
section.
20
Power up your computer system and run the
configuration program.
This completes the setup and configuration.