DIAGNOSTIC LEDS DESCRIPTION IN.YJ
D8, D9 & D10
D7
KIN
D2*
Power Ext
FLO
D3
D6
Power
D4
D5
Diagnostic LEDs (x13)
* D2 designation is not visible on the PCB, D2 is situated between component RD2 and E2.
Case
Designation
Description
Details
Action
1
Power
General 12V power
supply status
Should always be ON
If OFF, nothing will work.
Possible causes:
Input not connected
Check the input connection on P12
Installation main
breaker OFF
Check the main breaker of the installation.
Go to GFCI/RDC Trips section.
Short on one connector between 12V line
and near signal
Check following connectors in order:
P22 (C-pin 6); P17 (CO-pin 6);
P38 (RGB-pin 4), P33 (LIGHT-pin 3), P1
(pin 4)
Issue on board
Change the in.yj-V3 board
2
Power Ext
External 12V and 5V
power supplies status
Should always be ON
If OFF, external accessories
won't work.
Possible causes:
Short on one connector between 12V line
and near signal
Check following connectors in order:
P22 (C-pin 6); P17 (CO-pin6)
Short on one connector between 5V line
and near signal
Check following connectors in order:
P22 (C-pin 4); P17 (CO-pin 4);
P1 (pin 4); P8 (Pin 1)
3
D8, D9 & D10
MCU status
D8 should always blink, D9
and D10 are always OFF.
If not, possible causes:
The board is starting (power on)
Wait about 10 seconds
D8, D9 and D10 flashing in sync:
bootloader present, but there is no valid
firmware in the MCU memory
Power down the in.yj, insert an in.stik with
a valid software and reapply power
D8 always ON (more than 10 seconds),
D9 and D10 are always OFF: the in.yj is
in UPL state
Power down the in.yj, insert an in.stik with
a valid software and reapply power
Case
Designation
Description
Details
Action
D8 always ON, D9 flashing and D10 is
always OFF: software loading from an
in.stik in progress
Wait about 1 minute
POWER Led is OFF
Go to case #1
Issue on board
Change the in.yj-V3 board
4
D2
HL Relays (K2-K3)
cmd status
Should always be ON
If OFF, possible causes:
High Limit situation happens
Go to HL section
Remote heater cable or the probes cable
disconnected
Check remote heater cable or
Probe cable
F2 burnt (on CE models only)
Check F2
5
D6
Pump 1 low relay
(K6) cmd status
Should always be ON when the pump 1 is
running in low speed, and OFF otherwise.
If Led ON and pump
isn’t running:
Issue on pump
and connection
Check pump connection
F2 burnt
Check F2
If Led OFF and pump running:
Issue on relay K6
Change the in.yj-V3 board
6
D7
Pump 1 high relay
(K7) cmd status
Should always be ON when the pump
1 is running in high speed, and OFF
otherwise.
If Led ON and pump isn’t running:
Issue on pump and connection
Check pump connection
F2 burnt
Check F2
If Led OFF and pump running:
Issue on relay K7
Change the in.yj-V3 board
7
D5
Pump 2 relay (K5)
cmd status
or
Kinetic protection
(-KR option) relay (K5)
cmd status
Should always be ON when the pump 2 is
running, and OFF otherwise.
If Led ON and pump isn’t running:
Issue on pump and connexion
Check pump connection
F2 or F4 burnt
Check F2 and F4
If Led OFF and pump running:
Issue on relay K5
Change the in.yj-V3 board
8
D4
Regulation relay
(K4) cmd status
Should always be ON when the system is
heating and OFF otherwise.
If Led ON and no heating:
Issue heater connection
Check heater connection
F2 burnt
(on CE models only)
Check F2
Issue on remote heater
Change remote heater
If Led OFF and heating:
Issue on relay K4
Change the in.yj-V3 board