Y
Y
77
76
In.ye and in.yt European Electrical Specifications
Input rating:
230/240 V nominal (+5/-10 %)
50 Hz, (3 lines required with neutral), three-phased system 16 A Max per phase.
or
230/240 V nominal (+5/-10 %)
50 Hz, (2 lines required with neutral), dual-phase system 20 A Max per phase.
or
230/240 V nominal (+5/-10 %)
50 Hz, (1 line required with neutral), single-phase system 48 A max.
Heat.wav rating:
Voltage:
230/240 V, 50 Hz
Wattage:
3,8 kW at 230 V or 2,8 kW at 230 V
Flow rate:
A minimum of 18 GPM (68,1 LPM) is required
output
voltage
maximum
current
typical
device
ye-3
ye-5
yt-7
yt-8
yt-12
Output 1
230/240 V
15 FLA/60 LRA (in-rush)
Pump 2 high speed
•
•
•
•
Output 2
230/240 V
15 FLA/60 LRA (in-rush)
Ozonator
•
•
•
•
•
Output 3
230/240 V
15 FLA/60 LRA (in-rush)
Pump 2 low speed
•
•
•
•
Output 4
230/240 V
15 FLA/60 LRA (in-rush)
Pump 1 high speed
•
•
•
•
•
Output 5
230/240 V
15 FLA/60 LRA (in-rush)
Pump 1 low speed
•
•
•
•
•
Output 6
230/240 V
15 FLA/60 LRA (in-rush)
Pump 3 low speed
•
•*
1
•
Output 7
230/240 V
15 FLA/60 LRA (in-rush)
Circulation pump
•
•
Output 8
230/240 V
15 FLA/60 LRA (in-rush)
Pump 3 high speed
•
•
Output 9
230/240 V
20 FLA/80 LRA (in-rush)
Pump 4 high speed
•*
2
•
Output 10
230/240 V
15 FLA/60 LRA (in-rush)
Pump 4 low speed
•*
3
•
Output 11
230/240 V
15 FLA/60 LRA (in-rush)
Blower
•
Output 12
230/240 V
15 FLA/60 LRA (in-rush)
Pump 5
•
Direct out 1
230/240 V
5 A
Audio/video
•
•
•
•
Direct out 2
230/240 V
5 A
Audio/video
•
•
•
important
:
The maximum current for output 2 and heater output on fuse F1 may not exceed 20A.
The maximum current for outputs 4, 5 and direct 1 on fuse F2 may not exceed 20A.
The maximum current for outputs 1 and 3 on fuse F3 may not exceed 20A.
The maximum current for outputs 6 to 8 and direct 2 on fuse F21 may not exceed 20A.
The maximum current for outputs 11 and 12 on fuse F22 may not exceed 20A.
The maximum current for outputs 9 and 10 on fuse F23 may not exceed 20A.
The total maximum current for the fuses F22 and F23 may not exceed 30 A.
1. The typical accessory for the output 6 on a in.yt-8 is a pump 3 high speed.
2. It’s possible to configure the output 9 as a secondary heater on the in.yt-8.
3. The output 10 of the in.yt-8 is limited to 1A. This output is normally used with low current accessories.
*
*
*
European and International Standards
IEC 60335-1 : 2010 EN55014-1
IEC 60335-2-60 : 2002, A1 : 2004, A2 : 2008
EN55014-2
EN 60335-2-60 : 2003, A1 : 2005, A2 : 2008, A11 : 2011, A12 : 2010
EN61000-3-2
EN 60335-1 : 2012
EN61000-3-3
EN 62233 : 2008
Environmental Ratings
Operating temperature:
32˚F (0°C) to 136˚F (58˚C)
Storage temperature:
-13°F (-25°C) to 185°F (85°C)
Humidity:
Up to 85% RH, non condensing
Level of waterproofing:
IPX5
Mechanical
in.ye
Weight:
Up to 9.7 lbs (4.4 kg)
Dimensions (W x H x D):
19.60" x 10.75" x 4.98" (497 x 273 x 126 mm)
in.yt
Weight :
Up to 12 lbs (5.45 kg)
Dimensions (W x H x D):
19.6" x 14.5" x 5.1" (497 x 368 x 130 mm)
14
14
9919-101184-D
Rev. 02-2020
www.geckoalliance.com
© Groupe Gecko Alliance Inc., 2020
All trademarks or registered trademarks are the property of their respective owners.