SECTION 2 SPECIFICATIONS
31
2.1.8 OUTPUT
BANDWIDTH
The output bandwidth of the AMX-Series Power Source is listed below.
Full Power:
45
to 500 Hz (±0.10 db [± 1%])
20
to 5,000 Hz (±0.25 db [± 3%])
Small Signal:
5
to 40,000 Hz (±3 db [±30%])
(rated at 10% of full-scale output voltage)
2.1.9 LOAD TRANSIENT RESPONSE
Output load transient response for a 0-100% load induced step transient is approximately
5
μ
sec.
2.1.10 OUTPUT DC OFFSET
The DC offset present on the output of the AMX-Series Power Source is less than 10 mVDC
for the Models 105, 108, 112, 305, 308, 312, and 320-AMX; and less than 5 mVDC for the
Models 125, 140, 160, 345, 360, 390, and 3120-AMX.
2.1.11 OUTPUT PROTECTION
The output of the AMX-Series Power Source is protected through the use of electronic current
limiting. The output will automatically recover when the output fault is removed. Thermal
overload protection is also provided. Refer to paragraph 2.3.3 for details.
Note:
The programmable controller also provides programmable current
limit. Refer to the
UPC-Series Operation Manual
for details.
2.1.12 OUTPUT CONTROL CHARACTERISTICS
Output control characteristics, sync I/O signals and metering capabilities are determined by
the controller which is installed. Refer to the appropriate controller manual for details.
2.1.13 OUTPUT ISOLATION
The output of the AMX-Series is galvanically isolated from the chassis and input power.
Maximum allowable output Neutral to Chassis voltage is 150 VAC. (Refer to Paragraph
3.4.4 for special considerations when using transformer-coupled outputs.)
Содержание AMX Series
Страница 1: ...AMX SERIES AC POWER SOURCE OPERATION MANUAL PACIFIC POWER SOURCE ...
Страница 2: ......
Страница 8: ......
Страница 24: ...SECTION 2 SPECIFICATIONS 16 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 A MODEL 105 AMX OUTPUT RATING CURVES ...
Страница 25: ...SECTION 2 SPECIFICATIONS 17 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 B MODEL 108 AMX OUTPUT RATING CURVES ...
Страница 26: ...SECTION 2 SPECIFICATIONS 18 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 C MODEL 112 AMX OUTPUT RATING CURVES ...
Страница 27: ...SECTION 2 SPECIFICATIONS 19 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 D MODEL 125 AMX OUTPUT RATING CURVES ...
Страница 28: ...SECTION 2 SPECIFICATIONS 20 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 E MODEL 140 AMX OUTPUT RATING CURVES ...
Страница 29: ...SECTION 2 SPECIFICATIONS 21 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 F MODEL 160 AMX OUTPUT RATING CURVES ...
Страница 30: ...SECTION 2 SPECIFICATIONS 22 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 G MODEL 305 AMX OUTPUT RATING CURVES ...
Страница 31: ...SECTION 2 SPECIFICATIONS 23 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 H MODEL 308 AMX OUTPUT RATING CURVES ...
Страница 32: ...SECTION 2 SPECIFICATIONS 24 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 I MODEL 312 AMX OUTPUT RATING CURVES ...
Страница 33: ...SECTION 2 SPECIFICATIONS 25 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 J MODEL 320 AMX OUTPUT RATING CURVES ...
Страница 34: ...SECTION 2 SPECIFICATIONS 26 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 K MODEL 345 AMX OUTPUT RATING CURVES ...
Страница 35: ...SECTION 2 SPECIFICATIONS 27 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 L MODEL 360 AMX OUTPUT RATING CURVES ...
Страница 36: ...SECTION 2 SPECIFICATIONS 28 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 M MODEL 390 AMX OUTPUT RATING CURVES ...
Страница 37: ...SECTION 2 SPECIFICATIONS 29 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 N MODEL 3120 AMX OUTPUT RATING CURVES ...
Страница 45: ...SECTION 2 SPECIFICATIONS 37 2 2 2 INPUT POWER CONNECTION cont FIGURE 2 2 2 OUTLINE DRAWING MODEL 320 AMX ...
Страница 97: ...SECTION 4 OPERATION 89 4 6 1 SYSTEM ARCHITECTURE cont FIGURE 4 6 1 AMX SERIES SYSTEM ARCHITECTURE ...
Страница 114: ......