SECTION 3 INSTALLATION
74
3.4.5 MASTER - SLAVE PARALLELING INTERCONNECTIONS (M5283) (cont.)
ROUTINE POWER-UP, PARALLELED SYSTEM
The following procedure is recommended to turn on paralleled systems after it has been
verified that the installation is correct.
1.
Set the OUTPUT POWER switch of the Master Chassis (that which has the controller
installed) to the
OFF
position. The Output Power Switch of the Slave chassis is
disabled. Switch the INPUT POWER switch of the Master chassis to the
ON
position. Switch the INPUT POWER switch of the Slave chassis to the
ON
position.
This sequence is recommended so that the power amplifiers of the system operate in
a controlled manner during power-up. The controller will light up and begin to
display output data. The value of the output parameters will be set as programmed
in the UPC.
2.
Set the OUTPUT POWER switch of the Master chassis to the
ON/AUTO
position and
press the OUTPUT ENABLE button of the UPC to be
ON
.
CAUTION
DO NOT CONNECT ANY LOADS TO THE OUTPUT OF THE POWER SOURCE UNTIL THE
OUTPUT VOLTAGE AND FREQUENCY HAVE BEEN VERIFIED AS CORRECT.
APPLICATION OF IMPROPER VOLTAGE OR FREQUENCY CAN DAMAGE USER LOADS.
NOTE: Paralleled units must all be the same model. That is, only a
345-AMX may be paralleled with a 345-AMX, a 160-AMX may
only be paralleled with a 160-AMX. Connection with dissimilar
power sources will likely cause an output fault and may cause
damage to the equipment or the load.
It is the installer’s responsibility to meet all local and national
electrical codes when installing this equipment.
WARNING
LETHAL VOLTAGES ARE PRESENT AT THE OUTPUT TERMINALS OF THIS MACHINE!
Содержание AMX Series
Страница 1: ...AMX SERIES AC POWER SOURCE OPERATION MANUAL PACIFIC POWER SOURCE ...
Страница 2: ......
Страница 8: ......
Страница 24: ...SECTION 2 SPECIFICATIONS 16 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 A MODEL 105 AMX OUTPUT RATING CURVES ...
Страница 25: ...SECTION 2 SPECIFICATIONS 17 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 B MODEL 108 AMX OUTPUT RATING CURVES ...
Страница 26: ...SECTION 2 SPECIFICATIONS 18 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 C MODEL 112 AMX OUTPUT RATING CURVES ...
Страница 27: ...SECTION 2 SPECIFICATIONS 19 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 D MODEL 125 AMX OUTPUT RATING CURVES ...
Страница 28: ...SECTION 2 SPECIFICATIONS 20 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 E MODEL 140 AMX OUTPUT RATING CURVES ...
Страница 29: ...SECTION 2 SPECIFICATIONS 21 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 F MODEL 160 AMX OUTPUT RATING CURVES ...
Страница 30: ...SECTION 2 SPECIFICATIONS 22 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 G MODEL 305 AMX OUTPUT RATING CURVES ...
Страница 31: ...SECTION 2 SPECIFICATIONS 23 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 H MODEL 308 AMX OUTPUT RATING CURVES ...
Страница 32: ...SECTION 2 SPECIFICATIONS 24 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 I MODEL 312 AMX OUTPUT RATING CURVES ...
Страница 33: ...SECTION 2 SPECIFICATIONS 25 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 J MODEL 320 AMX OUTPUT RATING CURVES ...
Страница 34: ...SECTION 2 SPECIFICATIONS 26 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 K MODEL 345 AMX OUTPUT RATING CURVES ...
Страница 35: ...SECTION 2 SPECIFICATIONS 27 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 L MODEL 360 AMX OUTPUT RATING CURVES ...
Страница 36: ...SECTION 2 SPECIFICATIONS 28 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 M MODEL 390 AMX OUTPUT RATING CURVES ...
Страница 37: ...SECTION 2 SPECIFICATIONS 29 2 1 2 OUTPUT POWER cont FIGURE 2 1 2 N MODEL 3120 AMX OUTPUT RATING CURVES ...
Страница 45: ...SECTION 2 SPECIFICATIONS 37 2 2 2 INPUT POWER CONNECTION cont FIGURE 2 2 2 OUTLINE DRAWING MODEL 320 AMX ...
Страница 97: ...SECTION 4 OPERATION 89 4 6 1 SYSTEM ARCHITECTURE cont FIGURE 4 6 1 AMX SERIES SYSTEM ARCHITECTURE ...
Страница 114: ......