background image

 
 
 

User’s Manual 

 

Glite 965BW Gel Doc System  

 

Содержание Glite 965BW

Страница 1: ...User s Manual Glite 965BW Gel Doc System ...

Страница 2: ...2 ...

Страница 3: ... 6 BROWSE SCANNED IMAGES DELETE SCANNED IMAGES Examine Scanned Images 7 Delete Scanned Images 8 INSTALLATION OF AMBER FILTER SHEET 9 DISPLAY SCANS ON MONITOR OR PROJECTOR 10 FUNCTION MENU OPTIONS A Function Menu Options I 11 B Function Menu Options II 13 C Function Menu Options I Operation 14 D Function Menu Options II Operation 18 SPECIFICATIONS 22 ...

Страница 4: ... Port Scan Button Blue Light White Light Selection Switch Power On Off Button LCD Display Upper Lid Back Figure 2 DC power inlet USB 2 0 port VGA Out port Up Down Left Right menu button USB 2 0 Port Scan button Blue Light White Light selection switch Power Button LCD display Upper lid Figure 1 Figure 2 USB 2 0 port DC power Inside Figure 3 Upper Lid Lighting Area Lid Sensor Figure 3 Upper lid Ligh...

Страница 5: ...g into an electrical outlet 4 Push power button 5 Insert a USB flash drive 6 The Menu Mode icon will be displayed on top left side of the display Figure 4 7 Place a gel to the center of the surface of the lighting area Figure 5 6 8 Adjust image conditions then scan 5 Figure 5 Place the gel directly Menu mode icon Figure 4 Place gel to the center of the lighting area Figure 6 ...

Страница 6: ...unction Menu Options section for the details of all functions 6 Press SCAN button green LED will flash and CAPTURING will be displayed on the screen If thermal printer has been connected to the scanner Printing Yes No option will be displayed on the screen The scanned image will be automatically saved to the USB flash drive 7 Scanning of the gel sample is now complete It is suggested to slide the b...

Страница 7: ...ghting in Function Menu Options section for turning on White Epi or White Back Light options 7 Adjust the desired image quality through the Functions Menu if necessary Please check Function Menu Options section for the details of all functions 8 Press SCAN button green LED will flash and CAPTURING will be displayed on the screen If thermal printer has been connected to the scanner Printing Yes No ...

Страница 8: ...tions menu b When Scan Mode icon is highlighted press OK again to enter Play Mode c The Play Mode icon will display on top left corner of screen The captured images can then be reviewed one by one by pressing right left arrow buttons d Press up down arrow button the image can be zoomed in out and be moved upward downward and leftward rightward 8 ...

Страница 9: ... be deleted press OK to get into Function Description II b Press right arrow button to choose Edit Mode c Press up down arrow button to choose Delete Press right arrow button to select yes no to delete the file d Press up down arrow button to select Yes Press OK to save the setting The image is thus deleted ...

Страница 10: ...ning angle 3 Position the hole of the amber filter sheet in front of the hanging tab before hanging on the lid Figure 8 4 Place the amber filter sheet onto the filter hanging tab so the filter sheet hangs as shown in Figure 9 5 After hanging the filter on lid make sure the two bent areas placed against the lid 6 Once the installation is completed one may turn on the blue LED by pressing Scan butto...

Страница 11: ...using the VGA Out port 1 Set the television to VGA mode see monitor documentation for details 2 Connect the VGA cable to the video port of the TV monitor 3 Connect the other end of the VGA cable to the VGA port on the back of the scanner 4 Video output from the scanner can now be seen on the connected monitor including the full menu interface 11 ...

Страница 12: ...in this mode LED Lighting Mode To select the white light application for White Epi White Back Light image scan respectively Note this mode is available only when white light application is selected Exposure Mode To adjust the exposure time frame in this mode Target Type Mode To scan display the image in monochrome colorimetric and normal invert mode Default setting monochrome black white in normal...

Страница 13: ...ing f Quick View 1 sec 2 sec 3 sec off 2 sec is default setting g Slide Show Cycle 2 sec 3 sec 5 sec 10 sec 3 sec is default setting h Power Save 1 min 3 min 5 min 10 min off 1 min is default setting i Language English Japanese j Date setup date yyyy mm dd k Time setup time hh mm ss l Reset Yes No If YES reset all current settings back to factory default M About Unit Name S W version F W version U...

Страница 14: ... arrow button the image can be moved upward downward and leftward rightward Press to exit the Move Zoom Mode Auto Play Mode To automaticallyplay the captured images one by one Edit Mode To edit the captured images such as to rotate to flip or to delete the captured image etc Preview Mode To preview the captured images in a multi image thumbnail panel Set Up Mode Same as the Set Up Mode functions i...

Страница 15: ...into functional menu option list b Press right arrow button to choose LED Lighting Mode c Press up or down arrow button to choose light source White Epi White Back Light1 d Press OK to save the setting LED Lighting Mode Is selectable when in white light application 1 White Back Light mode is to scan gels such as SDS PAGE gels stained with coomassie blue preserved in a transparent manner 15 ...

Страница 16: ...K to get back to Scan mode Target Type Mode a When icon displays on the top left corner of the screen press OK to get into functional menu option list b Press right arrow button to choose Target Type Mode c Press up or down arrow button to choose the desired display mode B W B W Invert Color1 Color Invert1 d Press OK again to return to Scan Mode The default setting of the scanner is Black White in...

Страница 17: ...ose Set Up Mode C Press down arrow button to get into Setup Menu and select the desired settings items d Press right arrow button to get into settings mode Then press up or down arrow button to select the desired settings Press OK to save the settings e Press down arrow button to select other settings modes or press OK again to return to Scan Mode 17 ...

Страница 18: ...setting f Quick View 1 sec 2 sec 3 sec off 2 sec is default setting g Slide Show Cycle 2 sec 3 sec 5 sec 10 sec 3 sec is default setting h Power Save 1 min 3 min 5 min 10 min off 1 min is default setting i Language English Japanese j Date setup date yyyy mm dd k Time setup time hh mm ss l Reset Yes No If YES reset all current settings back to factory default M About Unit Name S W version F W versi...

Страница 19: ...display on top left corner of screen The captured images can then be reviewed one by one by pressing right arrow button d Press OK twice to get back to Scan Mode It will take few seconds to complete the process Move Zoom Mode e Move Zoom Mode Zoom in out captured images by pressing buttons Press up down arrow button and left right arrow button so the image can be moved upward downward and leftward...

Страница 20: ...lay Mode a When in Play Mode press OK to get into functional option list b Press right arrow button to choose Auto Play Mode then press OK c The captured image will automatically display on LCD screen one by one ...

Страница 21: ...into Edit Menu Rotate Flip Delete and select the desired setting item d Press right arrow button to get into setting mode Rotate Right 900 Delete No Left 900 Yes 1800 Flip Horizontal Vertical e Press up and down arrow button to select the desired setting Press OK to save the setting f Repeat step e for Delete setting or press OK again to return to Play Mode 21 ...

Страница 22: ... 1 X 1 2 X 2 3 X 3 and select the desired setting item Preview Mode 1 X 1 Display 1 image at a time 2 X 2 Display 4 images at a time 3 X 3 Display 9 images at a time d Press OK button to save the setting e The captured images will display on the screen based on the selected preview format setting Set Up Mode Same as the Set Up Mode described in Function Menu options I on page 17 22 ...

Страница 23: ... position III Lighting Light source Blue LED Light Epi White Light LED White Light White Back Light White back Light Panel VI Interface USB 2 0 Display Panel Build in 2 7 TFT LCD Output 1 USB 2 0 x2 Thermal printer and USB flash drive 2 VGA out 800x600 1024x768 V General Info Power AC Adaptor 12V 4 16A Dimension W x H x D 230x230x254mm 9 05x 9 05 x 10 in Gel Tools Shovel Amber Filter Sheet Weight ...

Страница 24: ...24 ...

Страница 25: ...25 ...

Страница 26: ...26 ...

Страница 27: ...27 ...

Страница 28: ...Manual Glite 965BW Gel Doc System Made in Taiwan PACIFIC IMAGE ELECTRONICS Co Ltd 7F No 23981 Sec 1 Datong Rd Xizhi Dist 221 New Taipei City Taiwan TEL 886 2 8692 1800 FAX 886 2 8692 1860 www scanace com tw 28 ...

Отзывы: