SKU 95591/95592/95593         

  For technical questions, please call 1-800-444-3353 

PAGE 6

gROUndIng

 

TO PREVEnT 

ELECTRIC SHOCK 

And dEATH FROM 

InCORRECT gROUndIng 

WIRE COnnECTIOn: 

Check with a qualified 

electrician if you are in doubt 

as to whether the outlet is 

properly grounded.  do not 

modify the power cord plug 

provided with the tool.  never 

remove the grounding prong 

from the plug.  do not use the 

tool if the power cord or plug 

is damaged.  If damaged, have 

it repaired by a service facility 

before use.  If the plug will not 

fit the outlet, have a proper 

outlet installed by a qualified 

electrician.

grounded Tools: Tools with Three 

Prong Plugs

3-Prong Plug and Outlet

1.  Tools marked with “Grounding Re-

quired” have a three wire cord and 

three prong grounding plug.  The 

plug must be connected to a properly 

grounded outlet.  If the tool should 

electrically malfunction or break 

down, grounding provides a low 

resistance path to carry electricity 

away from the user, reducing the risk 

of electric shock.  

(See 3-Prong Plug 

and Outlet.)

The grounding prong in the plug is 

2. 

connected through the green wire in-

side the cord to the grounding system 

in the tool.  The green wire in the cord 

must be the only wire connected to 

the tool’s grounding system and must 

never be attached to an electrically 

“live” terminal.  

(See 3-Prong Plug 

and Outlet.)

The tool must be plugged into an 

3. 

appropriate outlet, properly installed 

and grounded in accordance with all 

codes and ordinances.  The plug and 

outlet should look like those in the 

preceding illustration.  

(See 3-Prong 

Plug and Outlet.)

double Insulated Tools: Tools 

with Two Prong Plugs

Outlets for 2-Prong Plug

1.  Tools marked “Double Insulated” do 

not require grounding.  They have 

a special double insulation system 

which satisfies OSHA requirements 

and complies with the applicable 

standards of Underwriters Labora-

tories, Inc., the Canadian Standard 

Association, and the National Electri-

cal Code.  

(See Outlets for 2-Prong 

Plug.)

WARnIng

Содержание 95591 - .75 HP

Страница 1: ...eight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save th...

Страница 2: ...ollowing pages may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS REV 08b 09a SPECIFICATIONS Model 95591 Model 95592 Model 95593 Motor 115 V 60 Hz 4 A 3 4 HP 115 V 60 Hz 5...

Страница 3: ...out let only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit con tact a qualified electrician to install a polarized outlet Do not change the plug in an...

Страница 4: ...of electric shock or injury SPECIFIC SAFETY RULES Maintain labels and nameplates on 1 the Pump These carry important information If unreadable or miss ing contact Harbor Freight Tools for a replacemen...

Страница 5: ...ician install within 10 feet of where the Pump will be located a 115 volt GFCI electrical outlet that is dedicated only to the Pump Any outlet should be above the water line NEVER raise or lower the P...

Страница 6: ...nding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is 2 connected through the...

Страница 7: ...If you are using one extension cord 5 for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A If you are using an extension cord 6 out...

Страница 8: ...Assembly Diagram on page 13 WARNING Always make sure to turn off the electricity powering the Pump s electrical outlet and that the Pump is unplugged from its outlet prior to assembling the unit uncl...

Страница 9: ...e the stability of the Pump See Figure E Install an additional union not included or other means of separating the Dis 4 charge Pipe just above the floor to facilitate removal of the Pump if necessary...

Страница 10: ...dry Doing so will increase wear to the unit and possibly cause seal damage See Figure E Note This Pump has a built in thermal protector for the Motor which automatically shuts it off to avoid overhea...

Страница 11: ...ON All maintenance service or repairs not mentioned in this manual must only be performed by a qualified service technician TROUBLESHOOTING Problem Possible Solution Pump does not start Plug the Pump...

Страница 12: ...AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO PARTS LIST Part Description...

Страница 13: ...AGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 31 Power Cord Plug not shown Note Some parts are listed and shown for illustration purposes only and are not a...

Страница 14: ...perty or for incidental contingent special or con sequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so...

Отзывы: