PAGE 4

TOOL USE And CARE

disconnect the Power Cord Plug 

1. 

from the power source before 

making any adjustments, changing 

accessories, or storing the Sump 

Pump.  

Such preventive safety mea-

sures reduce the risk of starting the 

unit accidentally.

Store idle equipment out of reach 

2. 

of children and other untrained 

persons. 

Electrically-powered prod-

ucts are dangerous in the hands of 

untrained users.

Check for misalignment or binding 

3. 

of moving parts, breakage of parts, 

and any other condition that may 

affect this product’s operation.  If 

damaged, have the Sump Pump 

serviced before using.

  Many ac-

cidents are caused by poorly main-

tained equipment.

SERVICE

Service must be performed only by 

1. 

qualified repair personnel.  

Service 

or maintenance performed by unqual-

ified personnel could result in a risk of 

injury.

When servicing this product, use 

2. 

only identical replacement parts.  

Follow instructions in the “Inspec-

tion, Maintenance, And Cleaning” 

section of this manual. 

 Use of 

unauthorized parts or failure to follow 

maintenance instructions may create 

a risk of electric shock or injury.

SPECIFIC SAFETY RULES

Maintain labels and nameplates on 

1. 

the Pump.

  These carry important 

information.  If unreadable or miss-

ing, contact Harbor Freight Tools for a 

replacement.

2. 

Wear AnSI-approved 

safety impact eye gog-

gles when assembling 

the Pump.   

Using per-

sonal safety devices reduce the risk 

for injury.  Safety impact eye goggles 

are available from Harbor Freight 

Tools.

Use the right product for the job.  

3. 

There are certain applications for 

which this product was designed.  Do 

not use small tools, attachments, or 

equipment to do the work of larger in-

dustrial tools, attachments, or equip-

ment.  

Maintain a safe environment.  

4. 

Keep 

the area well lit.  Make sure there is 

adequate surrounding space.  Always 

keep the area free of obstructions, 

grease, oil, trash, and other debris.  

Do not use an electrically powered 

product in areas near flammable 

chemicals, dusts, and vapors.

5. 

Risk of electrical shock.  

Always disconnect the 

Pump from its power 

source before handling or 

making any adjustments to the tool.  

Always wear non-skid rubber boots 

when water is on the floor and you 

must unplug the Pump.  Make sure 

the electrical power source is a sepa-

rately fused, grounded, 3-wire type 

gFCI

 (Ground Fault Circuit Interrupt-

er) outlet.  

do not remove the 

ground prong on the Power Cord 

Plug.  do not use an extension 

cord.

Содержание 95591 - .75 HP

Страница 1: ...eight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save th...

Страница 2: ...ollowing pages may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS REV 08b 09a SPECIFICATIONS Model 95591 Model 95592 Model 95593 Motor 115 V 60 Hz 4 A 3 4 HP 115 V 60 Hz 5...

Страница 3: ...out let only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit con tact a qualified electrician to install a polarized outlet Do not change the plug in an...

Страница 4: ...of electric shock or injury SPECIFIC SAFETY RULES Maintain labels and nameplates on 1 the Pump These carry important information If unreadable or miss ing contact Harbor Freight Tools for a replacemen...

Страница 5: ...ician install within 10 feet of where the Pump will be located a 115 volt GFCI electrical outlet that is dedicated only to the Pump Any outlet should be above the water line NEVER raise or lower the P...

Страница 6: ...nding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is 2 connected through the...

Страница 7: ...If you are using one extension cord 5 for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A If you are using an extension cord 6 out...

Страница 8: ...Assembly Diagram on page 13 WARNING Always make sure to turn off the electricity powering the Pump s electrical outlet and that the Pump is unplugged from its outlet prior to assembling the unit uncl...

Страница 9: ...e the stability of the Pump See Figure E Install an additional union not included or other means of separating the Dis 4 charge Pipe just above the floor to facilitate removal of the Pump if necessary...

Страница 10: ...dry Doing so will increase wear to the unit and possibly cause seal damage See Figure E Note This Pump has a built in thermal protector for the Motor which automatically shuts it off to avoid overhea...

Страница 11: ...ON All maintenance service or repairs not mentioned in this manual must only be performed by a qualified service technician TROUBLESHOOTING Problem Possible Solution Pump does not start Plug the Pump...

Страница 12: ...AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO PARTS LIST Part Description...

Страница 13: ...AGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 31 Power Cord Plug not shown Note Some parts are listed and shown for illustration purposes only and are not a...

Страница 14: ...perty or for incidental contingent special or con sequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so...

Отзывы: