RETURN TO
TABLE OF
CONTENTS
INSPECTION & CLEANING
INSPECTION & CLEANING
NOTE
: If excessive debris is present, drain and flush the solution tank.
1. Close the shutoff valve.
2. Remove the filter bowl and screen.
3. Clean and rinse any debris in the filter assembly.
17
SOLUTION FLOW: NON-CHEMICAL INJECTION MODELS
SOLUTION FLOW: NON-CHEMICAL INJECTION MODELS
The Solution Control Knob is located on the top left corner of the control panel. The valve electrically turns on
and off with the Scrub Head. The knob controls how much solution passes through the valve when activated.
SOLUTION FLOW: S-28HD & OPTIONAL CHEMICAL INJECTION MODELS
SOLUTION FLOW: S-28HD & OPTIONAL CHEMICAL INJECTION MODELS
1. Place a 1-gallon chemical container in the holder in the battery compartment and remove the cap.
2. Insert the leader hose so that the end is resting on the bottom of the container and screw on the cap.
3. Match the mix ration dial on the control panel to the setting (in ounces per gallon) prescribed on the
chemical’s container.
4. Set the solution flow rate to low, medium, or high.
5. A solid green LED indicates that the system is automatically mixing the chemical while the machine
operates.
NOTE
: If the detergent is not priming, temporarily select a higher setting until detergent appears on the floor.
NOTE
: To purge old detergent, set the mixture dial to the highest ration and run until the leader hose line is
empty.