33
TRNT.BODYA
5055.45-A 021115-40
Installer information
Note: To test the gas pressure, turn off the gas supply to the gas stove before loosening test
point screws. Verify gas pressures with the gas stove lit and at the highest setting.
1. Remove back panel and locate the valve as seen in (Figure 69).
2. Locate the inlet and outlet test points on the valve (Figure 70).
After locating test ports loosen the screws within the ports using a flat-tip screwdriver.
3. Attach pressure gauge to the test ports.
4. Turn gas supply back on and verify gas pressure with the gas stove lit and on its highest setting.
5. After testing is finished turn off gas supply, remove the pressure gauges and re-tighten the
screws in the test points.
The pilot flame level can
be adjusted by turning the
adjustment screw, using a flat-tip
screwdriver, as seen on the valve
in (Figure 70).
Gas Pressure Testing Procedure
Pilot Flame Adjustment
Pilot flame level
adjustment screw
Pressure
modulator
device
Main gas
solenoid
Pilot
solenoid
Inlet pressure test
point
Manifold pressure
test point
Figure 68:
Trenton pilot
assembly.
Figure 69:
Control valve
location.
Figure 70:
Gas
control
valve.