background image

20

5055.45-A   021115-40

TRNT.BODYA

Installer information

Left blower fan

IFC Module

Right blower fan

Battery bay

Electrical  

connection

Gas  

connection

Gas valve

Trenton Gas Stove Rear Component

 

 

 

           

          

   

 

This gas stove is certified for use with 4” x 6

”coaxial venting components only. It is 

permitted to only use certified venting for this gas stove. See charts on page 19 for a 

list of approved venting components.

Venturi 

adjustment

Figure 30: 

Co-axial venting components.

Figure 31: 

Trenton rear side components.

Содержание trenton A series

Страница 1: ...NTON SERIES A FREESTANDING GAS STOVE INSTALLATION AND OPERATING INSTRUCTIONS 021115 40 5055 45 A SERIAL TRNT BODYA WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try t...

Страница 2: ...ustibles 15 Locating The gas stove 15 Vent terminal clearances 16 Vent terminal minimum clearances 16 Trenton Co Axial venting chart 17 Co Linear venting 18 Venting components 19 Trenton gas stove rear components 20 Gas and electrical connection 21 Screen mesh removal 22 Glass door removal 22 Log set installation 24 Glass door installation 26 Screen mesh installation 27 Accent lighting glass plate...

Страница 3: ... above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation un...

Страница 4: ...on and maintenance FORYOURSAFETY DonotinstalloroperateyourTrenton gasstovewithoutfirstreadingandunderstanding this manual Any installation or operational deviation from the following instructions voids the Pacific Energy FireplacesTM Warranty and may prove hazardous This gas stove and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of th...

Страница 5: ...ontact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to the gas stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Clothing or other flammable material should not be placed on or near the gas stove Any grill panel or door removed for servicing the...

Страница 6: ...urrent Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A in the USA Installation Requirements The Trenton gas stove installation and venting must conform to the current CAN CGA B149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA and approved per local codes Only qualified licensed or trained personne...

Страница 7: ...WN Arrow Key MODE Key Remote Control System Transmitter Remote Control with LCD Display System Description The Proflame Remote Transmitter uses a streamline design with a simple button layout and informative LCD display Figure 1 The remote transmitter is powered by 3 AAA type batteries A mode key is provided to index between the features and a thermostat key is used to turn on off or index through...

Страница 8: ...press the ON OFF Key on the Remote transmitter The Remote transmitter LCD display will only show the room temperature Figure 3 or Figure 4 At the same time the Receiver module will turn off the gas stove A single beep from the Receiver confirms reception of the command Manual Bypass of the Remote System If the batteries of the receiver or remote transmitter are low or depleted the gas stove can be...

Страница 9: ...e set temperature is now displayed Figure 10 To adjust the set point press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the remote transmitter The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point and the room temperatures As the room temperature gets closer to the set point the Smart Func...

Страница 10: ...ion press the Mode Key Figure 1 to index to the CPI mode icon Figure 15 Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode CPI Pressing the Down Arrow Key will return to IPI Figure 16 A single beep will confirm the reception of the command Remote dimmer control Light The light bulb function controls the exterior accent lighting To activate this function use the Mode Key Fig...

Страница 11: ...atteries are low a double beep will be emitted from the IFC module when it receives a command from the remote This is an alert for a low battery condition for the IFC board When the batteries are replaced a single beep will be emitted from the IFC module when a key is pressed See Initialization of the system for the first time on page 30 Warnings and Cautions WARNING Fire Hazard Can cause severe i...

Страница 12: ...edia such as logs and embers Inspect decorative media and burner assemblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean burners with a brush or vacuum cleaner paying close attention to burner ports b Check the pilot system for proper flame size and operation Clean pilot of soot dust or any other deposi...

Страница 13: ...the On Off switch for the fireplace to OFF turn off all electric power to the fireplace and call your service technician or gas supplier Note Sufficient time must be allowed for air to escape from lines if the unit is being lit for the first time 4 Push the On Off switch to the fireplace Off 5 Allow sufficient length of time minimum 5 minutes for any gas in the combustion chamber to escape If you ...

Страница 14: ... BODYA Installer information 26 3 4 30 5 8 21 15 16 24 Trenton Gas Stove Dimensions Dimensions Height 30 5 8 inches Width 26 3 4 inches Depth 21 15 16 inches Height to center of Flue Outlet 24 inches Figure 21 Trenton dimensions ...

Страница 15: ...LOCATION EXAMPLES INCLUDE MINIMUN CLEARANCES TO COMBUSTIBLE MATERIAL Locating the Gas stove Location Note The Trenton can be installed directly onto any flooring material without an additional floor protector Only requirement is that the floor be stable and strong enough to support the stove Note on corner placement Refer to minimum clearances as shown in Figure 22 Figure 23 Refer to Figure 24 for...

Страница 16: ... min Clearance under veranda porch deck or balcony a vent shall not terminate directly above a side walk or paved driveway which is located between two single family dwellings and serves both dwellings only permitted if veranda porch deck or balcony is fully open on a minimum of 2 sides beneath the floor as specified in CGA B149 Installation Codes Note local Codes or Regulation may require differe...

Страница 17: ...y be used but must be constrained to the boundaries of this chart A Maximum of three 3 90 elbows may be used Only one 1 90 elbow or combination of other elbows equaling 90 can be used without reducing horizontal run For each additional 90 elbow or an equal combination of elbows reduce horizontal vent run by 2 feet Ensure vent pipe is properly supported Damper Note The damper position is factory se...

Страница 18: ...top of chimney apply a bead of caulking to top of clay liner Slip vent terminal over liner and secure in place with lateral retaining bolts 5 For larger chimneys flashing will need to be constructed according to local building codes Simpson Duravent High Wind cap style Co Linear Kit w Flex 46DVA CL33 or Simpson Duravent Prairie cap style Co Linear Kit w Flex 46DVA CL33P are recommended for use wit...

Страница 19: ...Elbow 4DE90 4DE90B N A N A N A SV4EBR90 4DT EL90S 4DT EL90SB 46DVA E90 46DVA E90B 90 Elbow Swivel N A N A 4D90L 4D90LB SV4E90 SV4EB90 N A N A N A N A NOTE Mixing venting components from different manufacturers is inadvisable Figure 28 4 x 6 Rigid Piping Cross Reference Chart Description ICC EXCELDirect Metal Fab Sure Seal Security Secure Vent Selkirk Direct Temp DuraVent DirectVent Pro Ceiling Sup...

Страница 20: ...n Gas valve Trenton Gas Stove Rear Component This gas stove is certified for use with 4 x 6 coaxial venting components only It is permitted to only use certified venting for this gas stove See charts on page 19 for a list of approved venting components Venturi adjustment Figure 30 Co axial venting components Figure 31 Trenton rear side components ...

Страница 21: ... in Figure 32 Please see the gas supply section page 32 of the manual for requirement of the gas supply Electrical connection An IEC power cord is provided for connection to a standard wall outlet Note Do not plug the power cord in until installation has been completed Note Do not turn on the gas supply until installation has been completed Gas and Electrical Connections Figure 32 Trenton gas elec...

Страница 22: ...ove the top cover as shown in Figure 34 Make sure that the latticed oval panel in the center of the top cover does not slip off as it is not fastened to the larger cover 2 Raise the mesh screen cover as shown in Figure 35 and lift the mesh screen out Glass door removal Glass door retainer frame moved away from posts prior to lifting and remov ing Wing nut bolts Figure 33 Trenton gas stove with pac...

Страница 23: ...glass door so that it can be removed Figure 38 3 Remove the glass door together with the retainer frame that it is affixed to Log set pieces The large rear log above comes wrapped separately from the smaller logs The logs will be assembled in a specific order along with the glowing embers glass door and mesh screen Figure 39 Number one log Figure 40 Smaller logs in packaging Figure 41 Smaller logs...

Страница 24: ...le in the back of the 2nd log Figure 45 over the post located on the left hand side of the first log indicated by arrow Figure 45 Once 2nd log is mounted to the first log position the lower portion of 2nd log so that it is located close to the pilot without covering it and as close to the front of the firebox without interfering with the glass door once installed Log Set Installation Figure 42 Bur...

Страница 25: ...og as shown in Figure 48 making sure that the log does not cover the holes of the back row of the burner 4 Position 3rd log as shown in Figure 46 making surethatthelogdoesnotcovertheholesofthe back row of the burner The 3rd log has a hole in its underside which will fit onto a protruding tab on the burner Figure 42 Figure 46 3rd log placement Figure 47 4th log placement Figure 48 5th log placement...

Страница 26: ...the glass door frame into place Figure 51 making sure that the frame fits into the horizontal slot on the floor of the firebox 2 Align the glass door frame laterally so that its protruding positioning stud Figure 52 fits into the slot in the firebox This will line up the bolt slots at the top of the glass door frame to the firebox frame 3 Insert and tighten the bolts to secure the glass door frame...

Страница 27: ...e facing toward the log set once it is in place Figure 54 shows the front side of the screen mesh This side must be facing the doors once it is in place The screen mesh frame is not square and so it is important that it be oriented the correct way before insertion Figure 55 shows the screen mesh resting at a point where it is higher than the firebox frame and glass door frame immediately to its ri...

Страница 28: ...f the screen mesh once the holder is lowered into position Screen mesh Screen mesh Figure 59 shows the screen mesh holder in place with the holder channel keeping the screen mesh in its proper position Note it may be necessary to use a small amount of force to get the top of the screen mesh to fit into position of the screen mesh holder Return the top cover to its proper place Make sure that the l...

Страница 29: ... 7 The glass plate tray is located underneath the Trenton Figure 60 and is held in place by two wing nuts one on each side of the tray 1 The glass plate is easily installed from the front of the stove Figure 61 2 Slide a new glass plate into the holder located under the light tray Accent Lighting Glass Plates Figure 60 Trenton glass plate tray location Figure 61 Light tray access Changing the glas...

Страница 30: ...Initializing the System for the first time IFC Module The Proflame 2 Integrated Fireplace Control IFC module is a device that allows automatic ignition and pilot flame supervision and commands the functions of the hearth gas stove It s configured to control the ON OFF main burner operation giving the choice of both IPI intermittent pilot ignition and CPI continuous pilot ignition modes The Proflam...

Страница 31: ...l gas and open when using liquid propane Venturi adjustment is accessible through an opening in the rear cover See location on Figure 31 on page 20 Some adjustment may be required Damper Adjustment closed open Figure 66 Trenton damper adjustment Figure 67 Venturi adjustment Damper adjustment is located under the top cladding cover plate Factory setting is closed slowly open and adjust as necessary...

Страница 32: ...e The gas stove input rating is shown in the chart below A drip leg must be installed in the gas supply line going to the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve It is essential that a union or flanged connection not provided be installed just upstream of the valve to allow for repair or replacement of the ...

Страница 33: ...uge to the test ports 4 Turn gas supply back on and verify gas pressure with the gas stove lit and on its highest setting 5 After testing is finished turn off gas supply remove the pressure gauges and re tighten the screws in the test points The pilot flame level can be adjusted by turning the adjustment screw using a flat tip screwdriver as seen on the valve in Figure 70 Gas Pressure Testing Proc...

Страница 34: ...et Before installing the new orifice Loctite 567 Thread Sealant needs to be applied to the threads of the new orifice to ensure a proper seal when installed To replace the pilot orifice remove the pilot hood which is held in place by a spring First remove the spring and then remove the hood by pulling it up from the pilot bracket Figure 72 To remove the existing orifice insert a 5 32 or 4mm Allen ...

Страница 35: ... Decorative Tinted Glass Kit TRNT DECGLSA SIT Remote Transmitter GASC CNTRLA SIT Pilot Assembly GASC PILOTA Replacement Cast Iron Painted Top 5037 802 A Front 5037 803 A Side L 5037 807 A Side R 5037 808 A Door L 5037 811 A Door R 5037 812 A Top Grill 5037 806 A Ashlip 5037 809 A Legs set 5037 813 A Replacement Cast Iron Antique White Top 5037 802AW A Front 5037 803AW A Side L 5037 807AW A Side R ...

Страница 36: ... Installer information Wiring Diagram Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing LAMP COMFORT FAN PILOT BURNER ...

Страница 37: ...37 TRNT BODYA 5055 45 A 021115 40 Installer information Rating Label The Rating label as shown is located on the rear of the gas stove ...

Страница 38: ...38 5055 45 A 021115 40 TRNT BODYA Installer information ...

Страница 39: ...39 TRNT BODYA 5055 45 A 021115 40 Installer information ...

Страница 40: ...s LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pacificenergy net 2975 Allenby Rd Duncan BC V9l 6V8 ...

Отзывы: