Gas Pressure Testing Procedure
Note: This section covers gas pressure testing for both SIT and Maxitrol gas valves.
Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point
screws. Verify gas pressures with the fireplace lit and at the highest setting.
1. Remove surround.
2. Locate the inlet and outlet test points on the valve which can be seen in (Figure 41). After locating test
ports loosen the cap ends within the ports using a 3/16” Allan key.
3. If necessary, attach brass test extensions to the test ports. Extensions are not included (Figure 43).
4. Attach one end of hoses to brass extensions and the other end to the pressure gauge.
5. Turn gas supply back on and test pressures.
6. After testing is finished turn off gas supply, remove the pressure gauges, apply thread sealant to cap ends
and re-tighten (Figure 44).
Gas valve
Gas pressure
test ports
Figure 41: Gas valve location.
Pressure
out
Pressure
in
Figure 42: Gas pressure test ports.
Figure 43:
Installer supplied
gas valve test port
extensions.
Figure 44: Testing port caps with thread
sealant.
23
5055.990-A
130717-44
i30 TOFINO
Содержание TOFINO i30s
Страница 43: ...43 5055 990 A 130717 44 i30 TOFINO ...