Floor Protector
The stove may be installed on a combustible floor provided noncombustible ember protection is used.
This protection must extend as follows:
In Canada: 18" (457 mm) on the firing side and 8" (203 mm) to the other sides.
In USA: 16" (406 mm) to the front and 8" (203 mm) to the sides of the fuel loading door opening.
See the figures below. This protection is also required under the chimney connector and 2" (51 mm) beyond
each side if venting horizontally into a masonry chimney.
Canada Only
8" [203mm]
18" [457mm]
8" [203mm]
8" [203mm]
Minimum Width - 40'(1.02m)
Minimum Overall Depth - 50 1/2"(1.28m)
Non-combustible
floor protector
Figure 7: Floor protector - Canada only.ai
16" [406mm]
8" [203mm]
8" [203mm]
U.S.A. Only
Minimum Width - 34"(864mm)
Minimum Overall Depth - 40 1/2"(1.03m)
Non-combustible
floor protector
Figure 8: Floor protector - USA only.ai
SUPER / CLASSIC_030818-32
13
100000813