background image

18 

 

NEO 1.6 EU-En   200116-20

©PACIFIC ENERGY FIREPLACE 
PRODUCTS LTD.

Содержание NEO 1.6 EU A SERIES

Страница 1: ...a house fire may result For your safety follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area IMPORTAN...

Страница 2: ...loor Protector 12 Chimney and Connector 12 Combustion Air 12 Procedure 12 Optional Blower 13 Blower Operation 13 Troubleshooting 16 Replacement Parts 16 Firebrick Installation 17 Warranty Information...

Страница 3: ...n Smoke Control Areas when burning seasoned cordwood ENGLISH FRANCAIS ESPAN OL DATA CO Emissions at 13 O missions de CO 13 O m Emisiones de CO al 13 de O 0 12 Particle Emissions to 13 O missions de pa...

Страница 4: ...seasoned wood and ample combustion air will help to minimize annoying smoke emissions and creosote buildup Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are da...

Страница 5: ...es which will rapidly destroy metal surfaces and void warranty Burning these materials may result in the release of toxic fumes or render the stove ineffective and cause smoke The prohibition against...

Страница 6: ...bed to light a new fuel charge excessive smoke emission can occur Refueling must be carried out onto a suficient quantity of embers and ash that the new charge will ignite in a resonable period If the...

Страница 7: ...age such as cracks excessive corrosion burned out sections and excessive warping See website for descriptions and more detail Some warping of the baffle is normal up to 65cm Replace if the baffle has...

Страница 8: ...e door seal be maintained in good condition Periodically inspect seals and replace if necessary Follow instructions included in the WODC DG58 kit obtainable from your nearest Pacific Energy Dealer 5 D...

Страница 9: ...baffle up on one side and remove the cor responding brick rail by lifting up and off the mounting pins Lift the entire Baffle up and pull forward to disconnect from the supply tube Tilt baffle sideway...

Страница 10: ...a 7 16 12mm wrench remove lag bolts that secure the unit on both sides to bottom pallet Fig 2 Side Panel Installation 1 Carefully remove the panels from the box 2 Engage the tabs in the panel into th...

Страница 11: ...s of a competent or certified installer certified by the Wood Energy Technical Training program WETT in Canada Hearth Education Foundation HEARTH in U S A are strongly recommended BOTH CHIMNEY SYSTEM...

Страница 12: ...safety guidelines Procedure 1 Install all components to the chimney manufacturer s installation requirements Outside combustion air may be required consult local building codes See Combustion Air sec...

Страница 13: ...exposed chimney may ice up partially blocking the flue gases If blockage occurs flue gases may enter living space Note An outside air pipe shield is provided to place in front of the 4 pipe used to br...

Страница 14: ...f pipe Fireclay Flue liner Minimum 2 415m Ceiling Height Non combustible floor protector 1000 mm Hooded vent or 90 elbow turned down Ensure that the Masonry chimney meets all National and local fire a...

Страница 15: ...e floor protector 1000 mm Hooded vent or 90 elbow turned down The chimney may incorporate an offset To do this safely all sections of listed connector offset elbows and chimney section must be screwed...

Страница 16: ...NEO 1 6 WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION ITEM DESCRIPTION PART NO 2 Embossed Panel Set NE16 78375XX 3 Door Catch NE16 7825 4 Ash Lip NE16 5037701 6 Gasket Guide Glass Retainer NE16 7...

Страница 17: ...47 0 D 9 X 4 1 2 X 1 1 4 230 mm x 115 mm x 32 mm 5096 99 This package contains 13 full size firebricks as well as 2 various cut size bricks With the heater in the upright position install firebricks a...

Страница 18: ...18 NEO 1 6 EU En 200116 20 PACIFIC ENERGY FIREPLACE PRODUCTS LTD...

Страница 19: ...unit is operating correctly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defective part may be required...

Страница 20: ...ENERGY FIREPLACE PRODUCTS LTD PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 For technical support please contact your retailer Web site http www pacificenergy net Printed i...