Stove Dimensions
Baffle Removal
Chimney connector pipe should be disconnected from stove to clean and inspect. Only if this is not possible should you
remove baffle assembly. CAUTION: Ceramic blanket insulation is located on top of baffle. Do not use a vacuum in this area.
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR
INSULATION REMOVED.
Remove the retaining pin at the back of the firebox, just under the baffle. Lift baffle up on one side and remove the cor-
responding brick rail by lifting up and off the mounting pins. Lift the entire Baffle up and pull forward to disconnect from the
supply tube. Tilt baffle sideways to drop down and remove from firebox. Re-install baffle assembly in reverse order.
WARNING
Sweep/Clean chimney with baffle installed or be sure to plug the top of the
baffle tube in the back of the firebox before sweeping or cleaning. Failure to prevent
ash or soot from falling into the baffle tube will cause incorrect operation and will lead to
premature burn out of the tube or baffle.
NOTE: DIMENSION
DOES NOT INCLUDE
LEVELLING LEGS
FIG. #1
940mm
915mm
690mm
512mm
152mm