Operator Instructions

How to Test Your Wood

Add a large piece of wood to the stove when it has a large, hot bed of coals. It is dry if it is burning on more than one 
side within one minute. It is damp if it turns black and lights within three minutes.  If it sizzles, hisses and blackens with-
out igniting in five minutes it is soaked and should not be burnt

Lighting a Fire

WARNING: Never use chemicals or any other volatile liquid to start a fire.

1.  Adjust air control to “High” position (all the way to the left) and open door. 

2.  Place crumpled newspaper in the centre of the stove and crisscross with several pieces of dry kindling. Add a few 

small pieces of dry wood on top. 

3.  Ignite the paper and leave the door ajar approximately 13mm - 25mm until the wood kindling is fully engulfed in 

flame. 

4.  After the kindling is fully engulfed add a few small logs. Close door. 

5.  Begin normal operation after a good coal base exists and wood has charred. Operate on a medium to high setting, 

for up to 1 hour from cold start.

Curing of the Paint Finish

See Stove Bright user guide. When burning your stove for the first 2-3 times it is very important that the room be well 
ventilated. Open all windows and doors. 

HEALTH WARNING. 

The smoke from the curing process displaces oxygen. Small children, elderly folks and persons 

with existing breathing problems should vacate the area during the hot burn to avoid the discomfort of lost oxygen. The 
smoke is primarily Carbon Dioxide, and therefore non-toxic but uncomfortable. 

Normal Operation

1.  Set the air control to a desired setting. If smoke pours down across the glass (waterfall effect) this indicates you have 

shut the control down too soon or you are using too low a setting. The wide range control makes finding the desired 
setting for your application easy.  As every home's heating needs vary (ie. insulation, windows, climate, etc.) The 
proper setting can only be found by trial and error and should be noted for future burns. 

2.  To refuel, adjust air control to “High” position(all the way to the left), and give the fire time to brighten. Open the door 

slowly, this will prevent back puffing or flame roll-out. 

3.  Use wood of different shape, diameter and length ( recommended 16"(406mm)). Load your wood and try to place the 

logs so that the air can flow between them. Always use dry wood. 

4.  Do not load fuel to a height that exceeds the height of the back firebricks or in such a manner that would be 

hazardous when opening the door.

 

5.  For extended burns, unsplit logs are preferred. Remember to char the wood completely on "High" setting before 

adjusting air control to the "Low" setting for extended burn. Active secondary burning should be present above the 
wood load.  If it is not present or goes out shortly after, proper operating temperature has not been reached and the 
stove needs additional warm up time.

WARNING: Always keep loading door closed when burning. This stove is not designed for open door burning.

WARNING:  No alteration or modification of the combustion air control assembly is permitted. Any tampering will 
void warranty and could be very hazardous.

6

5055.600EU-A

Содержание NEO 1.2 EU A SERIES

Страница 1: ...y follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH...

Страница 2: ...Wood Selection 5 DO NOT BURN 5 How to Test Your Wood 6 Lighting a Fire 6 Curing of the Paint Finish 6 Normal Operation 6 Restarting from Hot Embers 7 Over Firing 7 Proper Draft 7 Ash Removal 7 Disposa...

Страница 3: ...Emissions to 13 O missions de particules 13 O Emisiones de part culas a 13 de O 51 mg Nm Smoke Temperature Temp rature fum es Temperatura humos 301 C Thermal output Puissance thermique Potencia t rmic...

Страница 4: ...for the tars and gases to ignite thus creating dense smoke and poor combustion This moisture laden smoke cools the chimney compounding the problem by offering the smoke the ideal place to condense In...

Страница 5: ...Maximum recomended size is 400mm x 100mm The wood must be less than 22 moisture content Higher efficiency and lower emissions generally result when burning air dried seasoned hardwoods as compared to...

Страница 6: ...imarily Carbon Dioxide and therefore non toxic but uncomfortable Normal Operation 1 Set the air control to a desired setting If smoke pours down across the glass waterfall effect this indicates you ha...

Страница 7: ...irebox the use of kiln dried lumber mill ends or paper waste and prolonged or continual use on a high burn setting Proper Draft Operation with the door open can cause excessive smoke Do not operate th...

Страница 8: ...ty Maintenance Continued 1 Burn only dry and well seasoned cord wood The denser or heavier the wood when dry the greater its heat value This is why hardwoods are generally preferred Green or wet wood...

Страница 9: ...his area is at the front center of the firebox 7 Do not store wood within stove installation clearances or within the space required for fuel loading and ash removal Keep the area around the stove cle...

Страница 10: ...ide air for combustion 4 Door gasket leakage Replace gasket Check latch Excessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Dra...

Страница 11: ...correctly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defec tive part may be required to be returned to...

Страница 12: ...Stove Dimensions 615mm 650mm 690mm 380mm Figure 1 NE12 24 Dimensions 807mm 841mm 688mm 420mm 89mm Figure 2 NE12 32 Dimensions NE12 24 Dimensions NE12 32 Dimensions Installation Instructions 12 120416...

Страница 13: ...e back of the panel but do not tighten 6 Push panel from the front toward the rear so that there is no play between the panel tabs and the front mounting bracket Also align the bottom of the panel so...

Страница 14: ...tions Figure 5 Slide panel in to place Tab Tab Tab Tab Panel Bracket Figure 4 Panel bracket ai Figure 6 Panel adjustments Align panel with unit base Figure 7 Base of panel and alignment 14 120416 24_...

Страница 15: ...lation building codes see Combustion Air section The services of a competent or certified installer are strongly recommended BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE APPROVED TO LOCAL AND NATIONAL ST...

Страница 16: ...screws installed with the crimped or male ends pointing down This will carry any liquid creosote or condensation back into the stove Installed according to the chimney chimney pipe manufacturer s inst...

Страница 17: ...aw outside air from behind the stove cut or drill a 3 1 4 83mm hole through the wall behind the unit Use an appropriate household 3 76mm inlet Connect the inlet to the intake starter section under the...

Страница 18: ...and H low and high operate blower speed control at desired setting Automatic To operate the blower automatically set the rocker switch on the side of the fan housing to Auto and set the speed control...

Страница 19: ...pace is well ventilated it is not necessary to extend air inlet to outside Ensure that the Masonry chimney meets all National Fire Protection Association and local building codes Have the chimney clea...

Страница 20: ...m Minimum Minimum 7 2 1m Ceiling Height 48 1219 mm Unit may be harder to start Please provide as much vertical length for the first section of pipe as possible The chimney may incorporate an offset To...

Страница 21: ...ntains 6 full size firebricks as well as 6 various cut size bricks With the heater in the upright position install firebricks as follows Place 4 full size firebricks C at the back of the heater first...

Страница 22: ...RIC 11 Door Gasket WODC NEODGKIT 12 Baffle Assembly NE12 787520 13 Brick rail NE12 7875 16 14 Rear Baffle Support NE12 7875 33 Replacement Parts NEO 1 2 WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPT...

Страница 23: ...060416 24_NEO 1 2 EU En 23 5055 600EU A...

Страница 24: ...hnical support please contact your retailer Web site http www pacificenergy net Printed in Canada 2016 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without pr...

Отзывы: