120416-24_NEO 1.2 EU-En

Operator Instructions

 Rating Label 

Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke 
control area. It is an offence to omit smoke from a chimney of a building, form a furnace or from any fixed boiler if 
located in a designated smoke control area. It is also an offence to acquire an "unauthorized fuel" for use within a smoke 
control area unless it is used in an "exempt" appliance (exempted from the controls which generally apply in the smoke 
control area).

The Secretary of State for Environment, Food and Rural Affairs has powers under the Act which authorise smokeless 
fuels or exempt appliances for use in smoke control areas in England. In Scotland and Wales this power rests with 
Ministers in the devolved administrations for those countries. Separate legislation, the Clean Air (Northern Ireland) Order 
1981, applies to Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas 
have been authorised in Regulations and that appliances used to burn solid fuel in those areas (other than "authorised" 
fuels) have been exempted by an order made and signed by the Secretary of State or Minister in the devolved 
administrations.

Further Information on the requirements of the Clean Air Act can be found here: http://smokecontrol.defra.gov.uk/

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of 
smoke control areas and you can contact them for details of Clean Air Act requirements.

ENGLISH

FRANCAIS

ESPAN�OL

DATA

CO Emissions 

(at 13% O²)%

Émissions de CO

(à 13% O m² )%

Emisiones de CO

(al 13% de O ²)%

0.21%

Particle Emissions to 

13% O²

Émissions de particules à

13% O ²

Emisiones de partículas a

13% de O ²

51 mg / 

Nm ³

Smoke Temperature

Tempèrature fumèes

Temperatura humos

301 °C

Thermal output 

Puissance thermique

Potencia térmica

5 kW

Efficiency

Rendiment

Rendimiento

75.2%

Min. d to front combustible 

materials

Min. d. pour sauvegarder matéri-

aux combustibles à l’avant

Min. d. a los materiales combus-

tibles delanteras

1000mm

Min. d to side combustible

materials

Min. d. pour sauvegarder matéri-

aux combustibles à côté

Min. d. a los materiales combus-

tibles laterales

500mm

Min. d to back combustible 

materials

Min d. pour sauvegarder matéri-

aux combustibles à côté arrière

Min. d. a los materiales combus-

tibles traseras

500mm

Class

Classe

Clase

1

Fuel Type - Wood

Combustible - Bois

Combustible - Madera

PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

2975 ALLENBY RD., DUNCAN, BC, CANADA  V9L 6V8

EN: 13240:2001 / A2:2005

NEO 1.2, ALDERLEA 1.2, NEOSTONE 1.2

5050.600EU

240216

16

Steel Freestanding room heater fired by 

wood fuel only.

Comply with the operating 

instructions. 

Use only recommended fuels. 

This appliance is suitable for long-term 

intermittent operation. 

This appliance cannot be connected to 

a common chimney.

Chauffe en acier indépendants uniquement 

de combustible de bois

Respecter les consignes d’exploitation. 

Utilisez uniquement des combustibles 

recommandés. 

Cet appareil est adapté pour un fonc-

tionnement intermittent à long terme. 

Cet appareil ne peut être raccordé à une 

cheminée commune.

Calentador de acero independiente de 

combustible solo de madera. 

Cumplir con las instrucciones de uso. 

Usar sólo los combustibles 

recomendados. 

Este aparato es adecuado para el funcio-

namiento intermitente a largo plazo. 

Este aparato no puede ser conectado a 

una chimenea común.

UK  -  The Clean Air Act 1993 and Smoke Control Areas.

The NEO 1.2 has been recommended for use in Smoke Control Areas when 
burning seasoned cord wood.

Operator Instructions

3

5055.600EU-A

Содержание NEO 1.2 EU A SERIES

Страница 1: ...y follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH...

Страница 2: ...Wood Selection 5 DO NOT BURN 5 How to Test Your Wood 6 Lighting a Fire 6 Curing of the Paint Finish 6 Normal Operation 6 Restarting from Hot Embers 7 Over Firing 7 Proper Draft 7 Ash Removal 7 Disposa...

Страница 3: ...Emissions to 13 O missions de particules 13 O Emisiones de part culas a 13 de O 51 mg Nm Smoke Temperature Temp rature fum es Temperatura humos 301 C Thermal output Puissance thermique Potencia t rmic...

Страница 4: ...for the tars and gases to ignite thus creating dense smoke and poor combustion This moisture laden smoke cools the chimney compounding the problem by offering the smoke the ideal place to condense In...

Страница 5: ...Maximum recomended size is 400mm x 100mm The wood must be less than 22 moisture content Higher efficiency and lower emissions generally result when burning air dried seasoned hardwoods as compared to...

Страница 6: ...imarily Carbon Dioxide and therefore non toxic but uncomfortable Normal Operation 1 Set the air control to a desired setting If smoke pours down across the glass waterfall effect this indicates you ha...

Страница 7: ...irebox the use of kiln dried lumber mill ends or paper waste and prolonged or continual use on a high burn setting Proper Draft Operation with the door open can cause excessive smoke Do not operate th...

Страница 8: ...ty Maintenance Continued 1 Burn only dry and well seasoned cord wood The denser or heavier the wood when dry the greater its heat value This is why hardwoods are generally preferred Green or wet wood...

Страница 9: ...his area is at the front center of the firebox 7 Do not store wood within stove installation clearances or within the space required for fuel loading and ash removal Keep the area around the stove cle...

Страница 10: ...ide air for combustion 4 Door gasket leakage Replace gasket Check latch Excessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Dra...

Страница 11: ...correctly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defec tive part may be required to be returned to...

Страница 12: ...Stove Dimensions 615mm 650mm 690mm 380mm Figure 1 NE12 24 Dimensions 807mm 841mm 688mm 420mm 89mm Figure 2 NE12 32 Dimensions NE12 24 Dimensions NE12 32 Dimensions Installation Instructions 12 120416...

Страница 13: ...e back of the panel but do not tighten 6 Push panel from the front toward the rear so that there is no play between the panel tabs and the front mounting bracket Also align the bottom of the panel so...

Страница 14: ...tions Figure 5 Slide panel in to place Tab Tab Tab Tab Panel Bracket Figure 4 Panel bracket ai Figure 6 Panel adjustments Align panel with unit base Figure 7 Base of panel and alignment 14 120416 24_...

Страница 15: ...lation building codes see Combustion Air section The services of a competent or certified installer are strongly recommended BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE APPROVED TO LOCAL AND NATIONAL ST...

Страница 16: ...screws installed with the crimped or male ends pointing down This will carry any liquid creosote or condensation back into the stove Installed according to the chimney chimney pipe manufacturer s inst...

Страница 17: ...aw outside air from behind the stove cut or drill a 3 1 4 83mm hole through the wall behind the unit Use an appropriate household 3 76mm inlet Connect the inlet to the intake starter section under the...

Страница 18: ...and H low and high operate blower speed control at desired setting Automatic To operate the blower automatically set the rocker switch on the side of the fan housing to Auto and set the speed control...

Страница 19: ...pace is well ventilated it is not necessary to extend air inlet to outside Ensure that the Masonry chimney meets all National Fire Protection Association and local building codes Have the chimney clea...

Страница 20: ...m Minimum Minimum 7 2 1m Ceiling Height 48 1219 mm Unit may be harder to start Please provide as much vertical length for the first section of pipe as possible The chimney may incorporate an offset To...

Страница 21: ...ntains 6 full size firebricks as well as 6 various cut size bricks With the heater in the upright position install firebricks as follows Place 4 full size firebricks C at the back of the heater first...

Страница 22: ...RIC 11 Door Gasket WODC NEODGKIT 12 Baffle Assembly NE12 787520 13 Brick rail NE12 7875 16 14 Rear Baffle Support NE12 7875 33 Replacement Parts NEO 1 2 WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPT...

Страница 23: ...060416 24_NEO 1 2 EU En 23 5055 600EU A...

Страница 24: ...hnical support please contact your retailer Web site http www pacificenergy net Printed in Canada 2016 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without pr...

Отзывы: