Installation Instructions
Spark arrester
rain cap
Certified
Chimney
Storm collar
Roof
flashing
Chimney Support
Wall Thimble
Alternate up and
out installation
Non-combustible
floor protector
Hooded vent or
90 elbow turned down
Attach to floor for
mobile homes
3" diameter air inlet with rodent screen.
If the crawl space is well ventilated it is not
necessary to extend air inlet to outside
as per Local
and Federal
codes
12"(305mm)
Minimum first
section of pipe
Chimney
connector
52" (1.32m)
Minimum
Minimum 7' (2.1m.)
Ceiling Height
48"
(1219 mm)
Unit may be harder
to start. Please provide
as much vertical length
for the first section
of pipe as possible
The chimney may incorporate
an offset. To do this safely,
all sections of listed connector,
offset elbows and chimney
section must be screwed
together by at least three sheet
metal screws per joint. The
chimney must be suitably
supported by the chimney
manufacturer's listed offset
support
Follow chimney manufacture specifcations for
distance between vent termination heigth and
chimney at roof line. Also consult local building
regulations.
*
*
Figure 11: Common residential venting configuration.
20
120416-24_ NEO 1.2
5055.600EU-A