Gas Pressure Testing Procedure
Note: To test the gas pressure, turn off the gas supply to the appliance before loosening
test point screws.
Verify gas pressures with the fireplace lit and at the highest setting.
1. Remove back panel and locate the valve as seen in Figure 17.
2. Locate the inlet and outlet test points on the valve which can be seen in Figure 18. After
locating test ports loosen the screws within the ports using a flat-tip screwdriver.
3. Attach pressure gauge to the test ports.
4. Turn gas supply back on and test pressures.
5. After testing is finished turn off gas supply, remove the pressure gauges and retighten the
screws in the test points.
Pilot Adjustment
The pilot flame level can be
adjusted by turning the adjustment
screw, using a flat-tip screwdriver,
seen on the valve in Figure 18.
Figure 17: Valve Location
Figure 18: Valve