8                                                                                                                                             FUSION_D1 081112-20

FIG. #3

Chimney

Roof fl ashing

Storm collar

*  4" diameter air inlet with rodent screen
*  If the crawl space is well ventilated it is not 
necessary to extend air inlet to outside

Spark arres-
tor rain cap

Radiation shield

Chimney Connector

Chimney Support

50 1/2" (1283 mm)

Minimum

Minimum 7' (2.1m.)

Ceiling Height

Attachment to fl oor for
mobile homes inside base

Non-combustible
fl oor protector

48"

(1219 mm)

3' (914 mm)

Minimum

Hooded vent or
90 elbow turned down

The chimney may incorpo-
rate an offset.  To do this 
safely, all sections of listed 
connector, offset elbows and 
chimney section must be 
screwed together by at least 
three sheet metal screws 
per joint.  The chimney must 
be suitably supported by 
the chimney manufacturer's 
listed offset support.

Listed Chimney and Chimney Connector

This appliance, when installed in a Mobile Home, must be installed with:

A. One of the following 6" double-wall connector systems:
  1. Security Model DL or DC 

 

5. Metal Fab Model DW

  2. Oliver MacLeod Model PV   

6. Ameri-Tec Model DBSP

  3. Energy Vent 

 

7. Industrial Chimney Model Excel Ultra-Black

  4. Selkirk Metalbestos Model DS 

8. Simpson Dura-Vent Model DVL

B. As well as one of the following compatible chimney systems - All parts 6":

CANADA ONLY: 

Security 

Pro-Jet 

ICC 

Selkirk 

Energy Vent

   

S2100 

H.T.3000 

Excel 2100  Sentinal CF  Commander 5000

Ceiling support 

XSF 

FCS 

SF 

CF-CSP 

CH6LCS

Rafter radiation shield 

 

RRS 

3' Chimney length 

XL3 

SL3 

L3 

CF-36SL 

CH636

2' Chimney length 

XL2 

SL2 

L2 

CF-24 

CH624

Roof fl ashing 

XFA 

RF17 

FA 

CF-FRA 

CH6TCF

Storm collar 

XSC 

SC 

SC 

CF-SC 

CH6SC

Spark arrestor rain cap  XCPE 

RCSA 

CPE 

CF-SA,CT 

CH6RC, SS

   
USA ONLY: 

Security 

Pro-Jet 

Security 

Pro-Jet 

Metalbestos  MetalFab 

Ameritech 

ICC 

Simpson Dura-Vent

   

S2100 

H.T.3000 

ASHT 

HT3103 

SSII 

2100 

TEC HS 

Excel 103HT  Dura/Plus  Dura Tech

Ceiling support 

XSF 

FCS 

SF 

FCS 

T-SFA 

TGCSP 

6PL-CS 

RDS/SQS 

SDP-SB 

SDP-SB

Rafter radiation shield 

 

RRS 

 

RRS 

T-JSMH 

TGRS

3' Chimney length 

XL3 

SL3 

L3 

SL3 

T-36 

TG3 

HS 36 

CL48 

SDP-P 

SDT-P

2' Chimney length 

XL2 

SL2 

L2 

SL2 

T-24 

TG2 

HS 24 

CL24 

SDP-P 

SDT-P

Roof fl ashing 

XFA 

RF17 

FA 

RF 

T-SFA 

TGF 

8RFFU 

VF 

SDP-F 

SDT-F

Storm collar 

XSC 

SC 

SC 

SC 

T-SC 

TGSC 

PL-ASCG 

SC 

SDP-SC 

SDT-SC

Spark arrestor rain cap  XCPE 

RCSA 

CPE 

RCSA 

T-CT 

TGC 

6PL-MPC 

RCS 

SDP-C 

SDT-C

Содержание Fusion

Страница 1: ...ions Contact local building or fire officialsaboutrestrictionsandinstallation inspection requirements in your area TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets the Environmental Protection Agency s July 1990 Particulate Emission Standards IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS MODEL FUSION SERIES D PRODUCT CODES FSND MBKC FSND SSC SERIAL ...

Страница 2: ...instructions may result in property damage bodily injury or even death Contents Safety and Maintenance 3 Maintenance Checks 4 Creosote 5 Formation and Need for Removal 5 Chimney Fires 5 In Case of a Chimney Fire 5 Avoiding a Chimney Fire 5 Stove Dimensions 6 Minimum Clearance to Combustibles 6 Mobile Home Installation 7 Clearances 7 Procedure 7 Listed Chimney and Chimney Connector 8 Residential In...

Страница 3: ...llow instructions included in the DR31 WDGKIT kit obtainable from your nearest Pacific Energy dealer 5 DOOR GLASS Do not slam loading door or otherwise impact glass When closing door make sure that no logs protrude to impact the glass If the glass gets cracked or broken it must be replaced before using the stove Replacement glass can be obtained from your dealer Use 8 13 16 x 15 1 4 x 5 mm Ceramic...

Страница 4: ...the Chimney System Top baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacumn on the grill openings in the back and bottom of the blower casing to remove any dust and debris Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has permanent warping ...

Страница 5: ...must be lived with Regular inspection and cleaning is the solution The use of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are dangerous Chimney inside temperatures can exceed 2000 F This causes much higher than normal temperatures in the chimney and on its exterior surfaces Thus ...

Страница 6: ... 22 3 16 13 1 2 30 5 8 19 25 3 8 25 3 8 11 1 4 11 1 4 15 3 16 6 1 2 26 5 8 15 17 11 1 2 17 20 3 16 28 5 8 4 1 4 4 1 4 18 3 8 18 3 8 8 1 4 8 1 4 22 3 8 22 3 8 17 28 5 8 18 3 16 9 1 2 23 1 4 32 3 4 36 1 2 27 9 16 23 3 4 8 11 16 Minimum Clearance to Combustibles FIG 1 Alcove Min Height 7 1 2 Max Depth 4 Stove Dimensions FIG 2 ...

Страница 7: ...tach stove to flooring using two 1 4 x 2 or longer lag screws Mobile Home Installation Warning Under no circumstances is this heater to be installed in a makeshift or temporary manner It may be fired only after the following conditions have been met DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE DO NOT INSTALL IN A SLEEPING ROOM Outside air supply must be used for Mobile Home...

Страница 8: ...odel DBSP 3 Energy Vent 7 Industrial Chimney Model Excel Ultra Black 4 Selkirk Metalbestos Model DS 8 Simpson Dura Vent Model DVL B As well as one of the following compatible chimney systems All parts 6 CANADA ONLY Security Pro Jet ICC Selkirk Energy Vent S2100 H T 3000 Excel 2100 Sentinal CF Commander 5000 Ceiling support XSF FCS SF CF CSP CH6LCS Rafter radiation shield RRS 3 Chimney length XL3 S...

Страница 9: ...ion within 10 feet 3 m The installation must meet all local codes Do not connect this unit to a chimney flue serving another appliance Double Wall Connector Use a listed double wall connector Install all components to the chimney connector manufacturer s installation requirements Single Wall Connector Smoke pipe must be as short and straight as possible use six inch diameter 24 gauge black pipe th...

Страница 10: ...ct Outside air may also be ducted from outside through the 4 diameter hole in the rear of the pedestal enclosure if you remove the cover plate Fig 6 Note This unit is not designed to be operated with the firing door open In addition to the obvious hazard of sparks landing on combustibles an open fire door will cause the heater to draw air from the living space and possibly cause suffocation 2 Room...

Страница 11: ...s it is very important that the room be well ventilated Open all windows and doors Smoke and fumes caused by the curing process may cause discomfort to some individuals Lighting a Fire WARNING Never use chemicals or any other volatile liquid to start a fire 1 Move air control lever to the left most position maximum firing rate and open door 2 Place crumpled newspaper in the centre of the heater an...

Страница 12: ... from your Pacific Energy dealer Re install baffle assembly in reverse order The two side pieces of insulation must be tight against the side rails Restarting After Extended or Overnight Burns 1 Open door and rake hot embers towards the front of the heater Add a couple of dry split logs on top of embers close door 2 Adjust air control to high control lever to the left and in just a few minutes log...

Страница 13: ...ebox Fig 8 8 Install the two screws through the flange of the blower into the rear shield Fig 9 9 Plug the power supply cord in and check blower operation Power Cord Clearance Tab Temperature Switch Blower Operation Proper blower speed matched with air control setting will ensure peak performance from your stove Operate as follows Air control set to low right most position operate blower speed con...

Страница 14: ...xcessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is set too high Set control lower 2 Not enough wood Unsplit wood is preferred for overnight burns 3 Draft too high Excessive chimney height and or diameter Stove Won t Burn 1 Comb...

Страница 15: ...A B C as shown below if you are installing the optional ash cleanout system or 1 full brick in place of A B if you are not installing the ash cleanout system Next install the side firebricks 4 full size each side Lastly install 3 full size firebricks against the rear wall Cet emballage contient 17 briques réfractaires à pleine grandeur ainsi que 4 briques coupées de diffé rentes grandeurs Si votre...

Страница 16: ...Black DRFS 4641 Stainless Steel 4654 9 Door Handle Assembly DRFS 4638 10 Boost Manifold 4105 11 Firebrick Set BRIC SSERA All parts may be ordered from your nearest Pacific Energy dealer Contact Pacific Energy for the location of the dealer 12a Brick Rail Set SSER RAILSET 13 Replacement Baffle Kit SSER DBAKIT 13a Baffle not sold separately SSER DBAF 13b Side Insulation not sold separately 5068 732 ...

Страница 17: ...FUSION_D1 081112 20 17 ...

Страница 18: ...18 FUSION_D1 081112 20 ...

Страница 19: ...N LES INSTRUCTIONS D INSTALLATION ET D OPÉRATION FOURNI AVEC L APPAREIL CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D INCENDIE POUR DES INFORMATIONS QUANT AUX RESTRICTIONS PERMIS D INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL ÉTATS UNIS SEULE MENT UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET...

Страница 20: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 4T8 Phone 250 748 1184 Web site http www pacificenergy net ...

Отзывы: