FUSION_D1 081112-20 13
Optional Blower
The optional blower kit (kit #WODC.BLOW) is equipped with a
three prong power cord and may be installed at any time. Fol-
low installation instructions supplied with the kit. Route power
supply cord away from heater.
Electrical rating: 115 volts A.C.-1.02 amps.
Fan output rating: 125 CFM
Blower Installation
1. Loosen the 2 screws at the center of the blower.
2. Install the temperature snap-switch assembly onto the
blower by placing the bracket over the screws.Fig. #7
3. Tighten the screws.
4. Ensure that the two wires are connected to the temperature
snap-switch.
5. Bend over the blower clearance tab and shown in Fig. #8.
6. Feed the power cord into the pedestal base and out through
the round hole near the bottom.
7. Slide the temperature snap-switch assembly up into the
space between the rear shield and the fi rebox, ensuring
that the temperature snap-switch contacts the fi rebox. Fig.
#8
8. Install the two screws through the fl ange of the blower into
the rear shield. Fig. #9
9. Plug the power supply cord in and check blower
operation.
Power Cord
Clearance
Tab
Temperature
Switch
Blower Operation
Proper blower speed matched with air control setting will ensure
peak performance from your stove. Operate as follows:
- Air control set to low (right-most position), operate blower
speed control on "Low".
- Air control set between low and high, operate blower speed
control at desired setting.
Automatic:
To operate the blower automatically, set the rocker
switch on the side of the fan housing to "Auto" and set the speed
control to desired setting. This will allow the fan to turn on as
the stove heats up to operating temperature. It will also shut
the blower off after the fi re has gone out and the unit cooled to
below a useful heat output range.
Manual:
To manually operate the blower, set the rocker switch
to "Man" and set the speed control to desired setting. This will by-
pass the sensing device and allow full control of the blower.
Switching from "Auto" to "Man" or selecting speed may be
done anytime.