Figure 28: Valve location.
Figure 29: Valve.
BRSL.BODYB
BDFD.BODYB
Gas Pressure Testing Procedure
Battery Holder
Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point screws.
Verify gas pressures with the fireplace lit and at the highest setting.
1.
Remove door, See Figure 35 on page 23 and locate the valve as seen in Figure 26.
2.
Locate the inlet and outlet test points on the valve which can be seen in Figure 28 and Figure 29. After locating the
ports loosen the screws within the ports using a flat-tip screwdriver.
3.
Attach pressure gauge to the test ports
4.
Turn gas supply back on and test pressures.
5.
After testing is finished turn off gas supply, remove the pressure gauges and retighten the screws in the test points.
Pilot Adjustment
The pilot flame level can be adjusted by turning the adjustment screw, using a flat-tip screwdriver, seen on
the valve in Figure 29.
21
5055.633-B
050216-44