3.
Enter 2, 3 or 4 digit then press #
Function Code 20 - AUXIN1
AUXIN1 is used for input device such as postal lock, infrared sensor, exit button, etc..AUXIN1 is associated with relay 1
1.
Log-in to programming
2.
Enter 20 then #
3. Enter
0= disable (default setting)
1= Enable control by relay 1 open door interval, see
function code 28
2= relay 1 control by AUXIN1
then press #
Function Code 21 - AUXIN2
AUXIN2 is used for input device such as postal lock, infrared sensor, exit button, etc.. AUXIN2 is associated with relay 2
1.
Log-in to programming
2.
Enter 21 then #
3. Enter
0= disable (default setting)
1= Enable control by relay 2 open door interval, see
function code 29
2= relay 2 control by AUXIN2
then press #
Function Code 22 - Do Not Disturb
If Do Not Disturb is enabled visitors can't call from the system
1.
Log-in to programming
2. Enter 21 then #
3. Entert 0= disable, 1= enable then press #
Function Code 23 Lock-out Count
The system will be disabled in about 60 seconds after pressing invalid access code or swiping invalid card as specified on the Lock-out Count.
1.
Log-in to programming
2. Enter 23 then #