file:///C|/PACH-CO.COM-2018/online_manual/aegis7000s.htm[6/13/2019 7:18:06 AM]
AeGIS 7000S SERIES
3. Enter 1-9 (default=3) then press #
Function Code 24 Alarm
The system will make have warning alarm if invalid code or card has been enter according to the setting on
function code 23.
1.
Log-in to programming
2. Enter 24 then #
3. Enter
0
= disable,
1
=disable system for 60 seconds and local beep (default setting),
2
= disable system for 60 seconds with no beep
3
= call directory (0-9) then press #
Function Code 25 Keypad Beep
Turn the keypad press beep On or Off
1.
Log-in to programming
2. Enter 25 then #
3. Enter 0= off, 1= On (default) then press #
Function Code 26 Door Beep
Turn the door beep On or Off
1.
Log-in to programming
2. Enter 26 then #
3. Enter 0= off, 1= On (default) then press #
Function Code 27 Talk Time
The amount of time the visitor can talk to the tenant. The timer starts as soon as the system is offhook.
1.
Log-in to programming
2. Enter 27 then #
3. Enter 10-240 seconds then press #
Function Code 28 Unlock Relay 1 Time
Relay 1 trigger time.