8. Using the handle on the Sliding Shaft Holder, index the table from
the Placement Position to the Reflow Position.
9. Select the desired profile or enter time and temperature parameters
for pre-heat, soak, and reflow phases. Those values will be shown
on the LCD display. See Figure 8. As each phase in the reflow
profile is entered, the LED indicator lights will show which phase
the process is in. See Figure 8.
Figure 8: Display and Data Entry Panel
10.Once the reflow profile has been completed, the reflow head will lift
up automatically and the cooling fan will turn on for 55 seconds.
Airflow from the cooling may be directed by loosening the locking
thumb screw on the fan and rotating it around its shaft.