M) Sliding Shaft Holder
Supports the rail system for the board holder. It is
also used to index the table from the Placement
Position to the Reflow Position using the handle
on the front.
N) Sensor 1 & 2 Inputs
The sensor inputs have been designed to use K-
type thermo-couples. Measured temperatures are
displayed on the LCD display, real time, and can
be interfaced to a PC using the TF 2000 Software
(optional) through the serial port on the back of the
TF 2000R.
O) Reflow Head
Contains the top-side heater and moves up and
down via an electric motor that is controlled
through the operations panel. A power
consumption indicator light is mounted onto the
front of the reflow head to indicate when it is
drawing power. The reflow head is clutched to
prevent excessive downward force from being
applied.
P) Nozzle
The nozzles for the TF 2000 are easily changed.
Several varieties are available. Use caution and
proper hand protection when changing nozzles, as
they will be hot.
**NOTE:
For TF2000 L/LE models, refer to Section 10 for a detailed
description of model differences.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание TF 2000
Страница 33: ...Page 32 of 67 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 37: ...Page 36 of 67 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 63: ...Page 62 of 67 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...