Figure 92.
22. "Lower Pump On? (or "Lower Pump Off?) is now
displayed. Use the YES and NO Keys to select
Lower Pump (from PACE Heat Wave preheat
system) On or Off during the Reflow cycle.
20. "Reflow Temp =" is now displayed. A number
depicting the desired top preheat temperature (in
degrees C or F as selected in the Set-Up Mode) is
shown on the bottom line of the Digital Readout.
Use the numbered keys to enter the desired Reflow
temperature. Always enter 3 numbers (including
any zeroes) to obtain the desired temperature. Press
and release the
STEP
Key.
21. "Reflow Blower =" is now displayed. A number
depicting the desired blower speed (1-9) is shown on
the bottom line of the Digital Readout. Use the
numbered keys to enter the correct number. Press
and release the
STEP
Key.
Figure 90.
Figure 91.
Operation
67