6.0 Trouble Shooting
More extensive trouble shooting, repair guides, videos, parts list are
provided online at
Or give us a call at 520-882-6598 with any questions
Problem
Cause
Solution
No power or
function
a. Unit is disconnected from
main electrical power
supply.
b. Main power switch is off.
c. Emergency stop button
engaged.
d. Magnetic switch not
engaged.
e. Shut off switch engaged.
f. Loose of broken wire.
g. Unable to determine
problem.
a. Verify electrical source and
connection.
b. Turn on main power
switch.
c. Release by turning
clockwise.
d. Close hood or wiggle hood
in closed position.
e. Lift specimen holder arm
or turn up shut off screw.
f. Disconnect power and
open up back panel.
Check for any loose or
broken wires
g. Contact service technician
Main motor
does not
operate
a. Hood not closed.
b. Overload activated (error
E1).
c. Transformer switch not
set to the correct voltage.
a. Close hood.
b. Press stop button and then
start button.
c. Set switch to correct
voltage.